Ultrasound Biomicroscopy in Narrow Peripheral Anterior Chamber Eyes With or Without Peripheral Anterior Synechiae
Hiroyo Hirasawa, Atsuo Tomidokoro, Shiho Kunimatsu‐Sanuki, Kōichi Mishima, Aiko Iwase, Goji Tomita, Makoto Araie
Abstract
Hiroyo Hirasawa, Atsuo Tomidokoro, Shiho Kunimatsu‐Sanuki, Kōichi Mishima, Aiko Iwase, Goji Tomita, Makoto Araie
Abstract
AIM: To compare the configurations of the anterior ocular segment including the anterior chamber (AC) angle and ciliary body between eyes with a narrow AC angle (ACA) with and without peripheral anterior synechiae (PAS). PATIENTS AND METHODS: One hundred and one eyes of 101 consecutive patients with a temporal peripheral AC depth one-quarter of the corneal thickness or less were included. Gonioscopy and ultrasound biomicroscopy were performed under light and dark conditions. The existence of PAS was further confirmed with compression gonioscopy with indentation. Eyes with findings suggestive of plateau iris configuration or those with glaucomatous optic neuropathy were carefully excluded. The biometric parameters including the ACA, the angle opening distance at 500 mum, the trabecular-ciliary process distance, the iris-zonule distance, and the scleral-ciliary process angle were determined. RESULTS: PAS were found in 43 (43%) of the 101 eyes. There were no differences in age, refractive error, or intraocular pressure between PAS-positive and PAS-negative eyes (P>0.1). ACA, iris-zonule distance, scleral-ciliary process angle under light and/or dark conditions were significantly smaller in the PAS-positive eyes than in the PAS-negative eyes (P<0.05). CONCLUSIONS: Shallow peripheral AC depth and relatively anteriorly located ciliary body was significantly associated with the presence of PAS in eyes with a narrow ACA.
OpenAlex reports 13 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
AIM: To compare the configurations of the anterior ocular segment including the anterior chamber (AC) angle and ciliary body between eyes with a narrow AC angle (ACA) with and without peripheral anterior synechiae (PAS). PATIENTS AND METHODS: One hundred and one eyes of 101 consecutive patients with a temporal peripheral AC depth one-quarter of the corneal thickness or less were included. Gonioscopy and ultrasound biomicroscopy were performed under light and dark conditions. The existence of PAS was further confirmed with compression gonioscopy with indentation. Eyes with findings suggestive of plateau iris configuration or those with glaucomatous optic neuropathy were carefully excluded. The biometric parameters including the ACA, the angle opening distance at 500 mum, the trabecular-ciliary process distance, the iris-zonule distance, and the scleral-ciliary process angle were determined. RESULTS: PAS were found in 43 (43%) of the 101 eyes. There were no differences in age, refractive error, or intraocular pressure between PAS-positive and PAS-negative eyes (P>0.1). ACA, iris-zonule distance, scleral-ciliary process angle under light and/or dark conditions were significantly smaller in the PAS-positive eyes than in the PAS-negative eyes (P<0.05). CONCLUSIONS: Shallow peripheral AC depth and relatively anteriorly located ciliary body was significantly associated with the presence of PAS in eyes with a narrow ACA.
Key concepts: Ultrasound biomicroscopy, Gonioscopy, Medicine, IRIS (biosensor), Ophthalmology, Ciliary body, Ciliary processes, Peripheral