We evaluated the effectiveness and practicality of using isoflurane as an inhalation anesthetic with oxygen as a gas carrier for American martens (Martes americana) in a field setting. Sixty-eight martens were trapped in the Waswanipi Cree Model Forest (Québec, Canada) from October to November 2005 and anesthetized with isoflurane in 100% oxygen (1 l/min) using a face mask. Induction setting of isoflurane was 3% for all animals. Mean (+/-SD) length of induction was 1.8+/-1.2 min. Maintenance isoflurane settings ranged from 1% to 4%. Procedures lasted an average of 16.4+/-7.1 min and were uneventful. Length of recovery, defined as the interval between the end of the procedure and animal release, was short (6.3+/-2.8 min), and well below reported lengths of recovery using injectable anesthetics (>/=70 min). As compared to open drop administration of isoflurane described in previous studies, the use of an anesthesia machine prevents the risk of potential fatal anesthetic overdose. We conclude that among anesthesia techniques currently available, isoflurane with oxygen as a gas carrier is a safe and useful field anesthetic in martens, when issues with equipment portability can be overcome.

Open-access reader

About this research paper

What this paper is about

We evaluated the effectiveness and practicality of using isoflurane as an inhalation anesthetic with oxygen as a gas carrier for American martens (Martes americana) in a field setting. Sixty-eight martens were trapped in the Waswanipi Cree Model Forest (Québec, Canada) from October to November 2005 and anesthetized with isoflurane in 100% oxygen (1 l/min) using a face mask. Induction setting of isoflurane was 3% for all animals. Mean (+/-SD) length of induction was 1.8+/-1.2 min. Maintenance isoflurane settings ranged from 1% to 4%. Procedures lasted an average of 16.4+/-7.1 min and were uneventful. Length of recovery, defined as the interval between the end of the procedure and animal release, was short (6.3+/-2.8 min), and well below reported lengths of recovery using injectable anesthetics (>/=70 min). As compared to open drop administration of isoflurane described in previous studies, the use of an anesthesia machine prevents the risk of potential fatal anesthetic overdose. We conclude that among anesthesia techniques currently available, isoflurane with oxygen as a gas carrier is a safe and useful field anesthetic in martens, when issues with equipment portability can be overcome.

Why it matters

OpenAlex reports 16 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We evaluated the effectiveness and practicality of using isoflurane as an inhalation anesthetic with oxygen as a gas carrier for American martens (Martes americana) in a field setting. Sixty-eight martens were trapped in the Waswanipi Cree Model Forest (Québec, Canada) from October to November 2005 and anesthetized with isoflurane in 100% oxygen (1 l/min) using a face mask. Induction setting of isoflurane was 3% for all animals. Mean (+/-SD) length of induction was 1.8+/-1.2 min. Maintenance isoflurane settings ranged from 1% to 4%. Procedures lasted an average of 16.4+/-7.1 min and were uneventful. Length of recovery, defined as the interval between the end of the procedure and animal release, was short (6.3+/-2.8 min), and well below reported lengths of recovery using injectable anesthetics (>/=70 min). As compared to open drop administration of isoflurane described in previous studies, the use of an anesthesia machine prevents the risk of potential fatal anesthetic overdose. We conclude that among anesthesia techniques currently available, isoflurane with oxygen as a gas carrier is a safe and useful field anesthetic in martens, when issues with equipment portability can be overcome.

Key concepts: Isoflurane, Intoxicative inhalant, Anesthetic, Anesthesia, Inhalation, Medicine, Biology, Toxicology

Related papers

Back to paper searchBrowse research topicsOriginal source
FIELD USE OF ISOFLURANE AS AN INHALANT ANESTHETIC IN THE AMERICAN MARTEN (MARTES AMERICANA) — Research Paper | ScholarLens