2013•Unpublished venueRequires access

Development of the micro region pH sensor using Ag/AgIO3 electrode method

Daiki Kaneko, Kazuyoshi Tsuchiya

Open publisher page 4 citations

Abstract

pH sensors are used for measuring pH of solutions etc in the beaker. It measures the whole part of samples collected inside the container. They are mostly made by a glass electrode method. Its merits are that has good potential reproducibility, and potential equilibrium time is faster than other pH measuring methods. pH sensors made by the glass electrode method are composed of glass electrode which has a glass thin film of approximately 0.05· mm· at the bottom, and reference electrode which has liquid junction at the bottom; besides silver chloride electrode was inserted in each electrode. Due to the complex design, the size becomes larger, thus it is required to downsize the pH sensor in order to measure the submicron size, such as cells which are around 10∼30[μm]. However, it is difficult to produce the smaller size by the glass electrode method, because KCl solution is used for internal liquid of a glass electrode and a reference electrode. Therefore, a new pH measuring method of Ag/AgIO3electrode method was developed in our laboratory. Ag/AgIO3electrode method does not require any internal liquid and is composed by an antimony electrode as the working electrode and an Ag/AgIO3electrode as the reference electrode. Therefore, we considered that it is able to create a micro pH sensor.

About this research paper

What this paper is about

pH sensors are used for measuring pH of solutions etc in the beaker. It measures the whole part of samples collected inside the container. They are mostly made by a glass electrode method. Its merits are that has good potential reproducibility, and potential equilibrium time is faster than other pH measuring methods. pH sensors made by the glass electrode method are composed of glass electrode which has a glass thin film of approximately 0.05· mm· at the bottom, and reference electrode which has liquid junction at the bottom; besides silver chloride electrode was inserted in each electrode. Due to the complex design, the size becomes larger, thus it is required to downsize the pH sensor in order to measure the submicron size, such as cells which are around 10∼30[μm]. However, it is difficult to produce the smaller size by the glass electrode method, because KCl solution is used for internal liquid of a glass electrode and a reference electrode. Therefore, a new pH measuring method of Ag/AgIO3electrode method was developed in our laboratory. Ag/AgIO3electrode method does not require any internal liquid and is composed by an antimony electrode as the working electrode and an Ag/AgIO3electrode as the reference electrode. Therefore, we considered that it is able to create a micro pH sensor.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

pH sensors are used for measuring pH of solutions etc in the beaker. It measures the whole part of samples collected inside the container. They are mostly made by a glass electrode method. Its merits are that has good potential reproducibility, and potential equilibrium time is faster than other pH measuring methods. pH sensors made by the glass electrode method are composed of glass electrode which has a glass thin film of approximately 0.05· mm· at the bottom, and reference electrode which has liquid junction at the bottom; besides silver chloride electrode was inserted in each electrode. Due to the complex design, the size becomes larger, thus it is required to downsize the pH sensor in order to measure the submicron size, such as cells which are around 10∼30[μm]. However, it is difficult to produce the smaller size by the glass electrode method, because KCl solution is used for internal liquid of a glass electrode and a reference electrode. Therefore, a new pH measuring method of Ag/AgIO3electrode method was developed in our laboratory. Ag/AgIO3electrode method does not require any internal liquid and is composed by an antimony electrode as the working electrode and an Ag/AgIO3electrode as the reference electrode. Therefore, we considered that it is able to create a micro pH sensor.

Key concepts: Glass electrode, Electrode, pH meter, Reference electrode, Working electrode, Materials science, Analytical Chemistry (journal), Quinhydrone electrode