1995•Applied Physics LettersRequires access

New CdTe photoconductor array detector for x-ray applications

S. S. Yoo, S. Sivananthan, J. P. Faurie, Brian G. Rodricks, J. Bai, Pedro A. Montano

Open publisher page 13 citations

Abstract

A CdTe photoconductor array x-ray detector was grown using molecular beam epitaxy (MBE) on a Si(100) substrate. The temporal response of the photoconductor arrays is as fast as 21 ps rise time and 38 ps full width half-maximum (FWHM). The spatial resolution of the photoconductor was good enough to provide 75 μm FWHM using a 50 μm synchrotron x-ray beam. A substantial number of x-ray photons are absorbed effectively within the MBE CdTe layer as observed from the linear response up to 15 keV. These results demonstrate that MBE grown CdTe is a suitable choice of the detector materials to meet the requirements for x-ray detectors.

About this research paper

What this paper is about

A CdTe photoconductor array x-ray detector was grown using molecular beam epitaxy (MBE) on a Si(100) substrate. The temporal response of the photoconductor arrays is as fast as 21 ps rise time and 38 ps full width half-maximum (FWHM). The spatial resolution of the photoconductor was good enough to provide 75 μm FWHM using a 50 μm synchrotron x-ray beam. A substantial number of x-ray photons are absorbed effectively within the MBE CdTe layer as observed from the linear response up to 15 keV. These results demonstrate that MBE grown CdTe is a suitable choice of the detector materials to meet the requirements for x-ray detectors.

Why it matters

OpenAlex reports 13 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A CdTe photoconductor array x-ray detector was grown using molecular beam epitaxy (MBE) on a Si(100) substrate. The temporal response of the photoconductor arrays is as fast as 21 ps rise time and 38 ps full width half-maximum (FWHM). The spatial resolution of the photoconductor was good enough to provide 75 μm FWHM using a 50 μm synchrotron x-ray beam. A substantial number of x-ray photons are absorbed effectively within the MBE CdTe layer as observed from the linear response up to 15 keV. These results demonstrate that MBE grown CdTe is a suitable choice of the detector materials to meet the requirements for x-ray detectors.

Key concepts: Full width at half maximum, Molecular beam epitaxy, X-ray detector, Cadmium telluride photovoltaics, Detector, Optics, Materials science, Optoelectronics

Related papers

Back to paper searchBrowse research topicsOriginal source
New CdTe photoconductor array detector for x-ray applications — Research Paper | ScholarLens