1987Clinical Orthopaedics and Related ResearchRequires access

Apparent Changes in the Alignment of the Femoral Component in Hip Arthroplasties Associated with Limb Positioning

Stuart B. Goodman, Joel Rubenstein, J. Schatzker, LEON KADISH, Victor Fornasier

Open publisher page 17 citations

Abstract

Three femoral components (one cemented and one uncemented straight-stem Muller and one uncemented Anatomic Medullary Locking) were placed into cadaveric or commercially available plastic femora to establish that rotation of the femur can simulate changes in femoral component alignment on the anteroposterior radiograph. The change in alignment is governed by the position of the prosthesis within the femoral canal. If the stem of the prosthesis is positioned posteriorly in the canal, external rotation simulates valgus; internal rotation results in a varus orientation. If the prosthetic stem is located anteriorly in the canal, the reverse is true. This effect was noted in all specimens for values as small as 20 degrees of rotation. Because a change in the position of a prosthesis may signify loosening, it is recommended that standardized positioning techniques be used for radiographic analysis of total hip arthroplasties.

About this research paper

What this paper is about

Three femoral components (one cemented and one uncemented straight-stem Muller and one uncemented Anatomic Medullary Locking) were placed into cadaveric or commercially available plastic femora to establish that rotation of the femur can simulate changes in femoral component alignment on the anteroposterior radiograph. The change in alignment is governed by the position of the prosthesis within the femoral canal. If the stem of the prosthesis is positioned posteriorly in the canal, external rotation simulates valgus; internal rotation results in a varus orientation. If the prosthetic stem is located anteriorly in the canal, the reverse is true. This effect was noted in all specimens for values as small as 20 degrees of rotation. Because a change in the position of a prosthesis may signify loosening, it is recommended that standardized positioning techniques be used for radiographic analysis of total hip arthroplasties.

Why it matters

OpenAlex reports 17 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Three femoral components (one cemented and one uncemented straight-stem Muller and one uncemented Anatomic Medullary Locking) were placed into cadaveric or commercially available plastic femora to establish that rotation of the femur can simulate changes in femoral component alignment on the anteroposterior radiograph. The change in alignment is governed by the position of the prosthesis within the femoral canal. If the stem of the prosthesis is positioned posteriorly in the canal, external rotation simulates valgus; internal rotation results in a varus orientation. If the prosthetic stem is located anteriorly in the canal, the reverse is true. This effect was noted in all specimens for values as small as 20 degrees of rotation. Because a change in the position of a prosthesis may signify loosening, it is recommended that standardized positioning techniques be used for radiographic analysis of total hip arthroplasties.

Key concepts: Medicine, Cadaveric spasm, Medullary cavity, Femur, Prosthesis, Radiography, Valgus, Orthodontics

Related papers

Back to paper searchBrowse research topicsOriginal source
Apparent Changes in the Alignment of the Femoral Component in Hip Arthroplasties Associated with Limb Positioning — Research Paper | ScholarLens