2013•CirculationOpen access

Efficacy and Safety of a 4-Factor Prothrombin Complex Concentrate in Patients on Vitamin K Antagonists Presenting With Major Bleeding

Ravi Sarode, Truman John Milling, Majed A. Refaai, Antoinette Mangione, Astrid Schneider, Billie L. Durn, Joshua Norkin Goldstein

Open full text 810 citations

Abstract

BACKGROUND: Patients experiencing major bleeding while taking vitamin K antagonists require rapid vitamin K antagonist reversal. We performed a prospective clinical trial to compare nonactivated 4-factor prothrombin complex concentrate (4F-PCC) with plasma for urgent vitamin K antagonist reversal. METHODS AND RESULTS: In this phase IIIb, multicenter, open-label, noninferiority trial, nonsurgical patients were randomized to 4F-PCC (containing coagulation factors II, VII, IX, and X and proteins C and S) or plasma. Primary analyses examined whether 4F-PCC was noninferior to plasma for the coprimary end points of 24-hour hemostatic efficacy from start of infusion and international normalized ratio correction (≤1.3) at 0.5 hour after end of infusion. The intention-to-treat efficacy population comprised 202 patients (4F-PCC, n=98; plasma, n=104). Median (range) baseline international normalized ratio was 3.90 (1.8-20.0) for the 4F-PCC group and 3.60 (1.9-38.9) for the plasma group. Effective hemostasis was achieved in 72.4% of patients receiving 4F-PCC versus 65.4% receiving plasma, demonstrating noninferiority (difference, 7.1% [95% confidence interval, -5.8 to 19.9]). Rapid international normalized ratio reduction was achieved in 62.2% of patients receiving 4F-PCC versus 9.6% receiving plasma, demonstrating 4F-PCC superiority (difference, 52.6% [95% confidence interval, 39.4 to 65.9]). Assessed coagulation factors were higher in the 4F-PCC group than in the plasma group from 0.5 to 3 hours after infusion start (P<0.02). The safety profile (adverse events, serious adverse events, thromboembolic events, and deaths) was similar between groups; 66 of 103 (4F-PCC group) and 71 of 109 (plasma group) patients experienced ≥1 adverse event. CONCLUSIONS: 4F-PCC is an effective alternative to plasma for urgent reversal of vitamin K antagonist therapy in major bleeding events, as demonstrated by clinical assessments of bleeding and laboratory measurements of international normalized ratio and factor levels. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT00708435.

About this research paper

What this paper is about

BACKGROUND: Patients experiencing major bleeding while taking vitamin K antagonists require rapid vitamin K antagonist reversal. We performed a prospective clinical trial to compare nonactivated 4-factor prothrombin complex concentrate (4F-PCC) with plasma for urgent vitamin K antagonist reversal. METHODS AND RESULTS: In this phase IIIb, multicenter, open-label, noninferiority trial, nonsurgical patients were randomized to 4F-PCC (containing coagulation factors II, VII, IX, and X and proteins C and S) or plasma. Primary analyses examined whether 4F-PCC was noninferior to plasma for the coprimary end points of 24-hour hemostatic efficacy from start of infusion and international normalized ratio correction (≤1.3) at 0.5 hour after end of infusion. The intention-to-treat efficacy population comprised 202 patients (4F-PCC, n=98; plasma, n=104). Median (range) baseline international normalized ratio was 3.90 (1.8-20.0) for the 4F-PCC group and 3.60 (1.9-38.9) for the plasma group. Effective hemostasis was achieved in 72.4% of patients receiving 4F-PCC versus 65.4% receiving plasma, demonstrating noninferiority (difference, 7.1% [95% confidence interval, -5.8 to 19.9]). Rapid international normalized ratio reduction was achieved in 62.2% of patients receiving 4F-PCC versus 9.6% receiving plasma, demonstrating 4F-PCC superiority (difference, 52.6% [95% confidence interval, 39.4 to 65.9]). Assessed coagulation factors were higher in the 4F-PCC group than in the plasma group from 0.5 to 3 hours after infusion start (P<0.02). The safety profile (adverse events, serious adverse events, thromboembolic events, and deaths) was similar between groups; 66 of 103 (4F-PCC group) and 71 of 109 (plasma group) patients experienced ≥1 adverse event. CONCLUSIONS: 4F-PCC is an effective alternative to plasma for urgent reversal of vitamin K antagonist therapy in major bleeding events, as demonstrated by clinical assessments of bleeding and laboratory measurements of international normalized ratio and factor levels. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT00708435.

Why it matters

OpenAlex reports 810 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: Patients experiencing major bleeding while taking vitamin K antagonists require rapid vitamin K antagonist reversal. We performed a prospective clinical trial to compare nonactivated 4-factor prothrombin complex concentrate (4F-PCC) with plasma for urgent vitamin K antagonist reversal. METHODS AND RESULTS: In this phase IIIb, multicenter, open-label, noninferiority trial, nonsurgical patients were randomized to 4F-PCC (containing coagulation factors II, VII, IX, and X and proteins C and S) or plasma. Primary analyses examined whether 4F-PCC was noninferior to plasma for the coprimary end points of 24-hour hemostatic efficacy from start of infusion and international normalized ratio correction (≤1.3) at 0.5 hour after end of infusion. The intention-to-treat efficacy population comprised 202 patients (4F-PCC, n=98; plasma, n=104). Median (range) baseline international normalized ratio was 3.90 (1.8-20.0) for the 4F-PCC group and 3.60 (1.9-38.9) for the plasma group. Effective hemostasis was achieved in 72.4% of patients receiving 4F-PCC versus 65.4% receiving plasma, demonstrating noninferiority (difference, 7.1% [95% confidence interval, -5.8 to 19.9]). Rapid international normalized ratio reduction was achieved in 62.2% of patients receiving 4F-PCC versus 9.6% receiving plasma, demonstrating 4F-PCC superiority (difference, 52.6% [95% confidence interval, 39.4 to 65.9]). Assessed coagulation factors were higher in the 4F-PCC group than in the plasma group from 0.5 to 3 hours after infusion start (P<0.02). The safety profile (adverse events, serious adverse events, thromboembolic events, and deaths) was similar between groups; 66 of 103 (4F-PCC group) and 71 of 109 (plasma group) patients experienced ≥1 adverse event. CONCLUSIONS: 4F-PCC is an effective alternative to plasma for urgent reversal of vitamin K antagonist therapy in major bleeding events, as demonstrated by clinical assessments of bleeding and laboratory measurements of international normalized ratio and factor levels. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT00708435.

Key concepts: Medicine, Vitamin K antagonist, Prothrombin complex concentrate, Confidence interval, Hemostasis, Adverse effect, Internal medicine, Population

Related papers

Back to paper searchBrowse research topicsOriginal source
Efficacy and Safety of a 4-Factor Prothrombin Complex Concentrate in Patients on Vitamin K Antagonists Presenting With Major Bleeding — Research Paper | ScholarLens