2005Journal of EchocardiographyOpen access

Efficacy of 1.5 Harmonic Imaging for Intravenous Myocardial Contrast Echocardiography

Tsutomu Toshida, Fuminobu Ishikura, Toshihiko Asanuma, Akiko Iwata, Ayako Miki, Kentaro Otani, Shintaro Beppu

Open full text 3 citations

Abstract

Background. Although second harmonic (2H) imaging is utilized to minimize the tissue signals in myocardial contrast echocardiography (MCE), the native tissue harmonic signal is sufficiently high enough to cause a misreading of myocardial opacification when high mechanical index (MI) is used.Purpose. The backscattered signal from microbubbles at high MI is broadband, while it is narrowband at low MI. Therefore, the bubble/tissue signal ratio is expected to be high between the fundamental signal and 2H frequencies at high MI. Our aim was to elucidate the efficacy of a new imaging method using an in-between frequency, denoted as 1.5 harmonic (1.5H) imaging.Methods. Six open-chest dogs were examined using Toshiba APLIO with 1.5H and conventional 2H system. The transmitting/receiving frequencies were 2.3/3.3 MHz for 1.5H and 1.4/2.8MHz for 2H imaging, respectively. Intermittent MCE was performed at a MI of 1.6 after injection of Levovist®, and baseline intensity and peak intensity of opacification of the ventricular septum were measured.Results. While baseline intensity of the septum was significantly lower using 1.5H than 2H (26±4 vs. 43±14 gray level, p<0.001), the opacification after Levovist was significantly higher using 1.5H than 2H (91±32 vs. 51±38, p<0.001). Due to the combination of these effects, visual recognition of myocardial opacification was quite superior with 1.5H imaging.Conclusion. The 1.5H imaging system provides superb contrast opacification when using high MI.

Open-access reader

About this research paper

What this paper is about

Background. Although second harmonic (2H) imaging is utilized to minimize the tissue signals in myocardial contrast echocardiography (MCE), the native tissue harmonic signal is sufficiently high enough to cause a misreading of myocardial opacification when high mechanical index (MI) is used.Purpose. The backscattered signal from microbubbles at high MI is broadband, while it is narrowband at low MI. Therefore, the bubble/tissue signal ratio is expected to be high between the fundamental signal and 2H frequencies at high MI. Our aim was to elucidate the efficacy of a new imaging method using an in-between frequency, denoted as 1.5 harmonic (1.5H) imaging.Methods. Six open-chest dogs were examined using Toshiba APLIO with 1.5H and conventional 2H system. The transmitting/receiving frequencies were 2.3/3.3 MHz for 1.5H and 1.4/2.8MHz for 2H imaging, respectively. Intermittent MCE was performed at a MI of 1.6 after injection of Levovist®, and baseline intensity and peak intensity of opacification of the ventricular septum were measured.Results. While baseline intensity of the septum was significantly lower using 1.5H than 2H (26±4 vs. 43±14 gray level, p<0.001), the opacification after Levovist was significantly higher using 1.5H than 2H (91±32 vs. 51±38, p<0.001). Due to the combination of these effects, visual recognition of myocardial opacification was quite superior with 1.5H imaging.Conclusion. The 1.5H imaging system provides superb contrast opacification when using high MI.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Background. Although second harmonic (2H) imaging is utilized to minimize the tissue signals in myocardial contrast echocardiography (MCE), the native tissue harmonic signal is sufficiently high enough to cause a misreading of myocardial opacification when high mechanical index (MI) is used.Purpose. The backscattered signal from microbubbles at high MI is broadband, while it is narrowband at low MI. Therefore, the bubble/tissue signal ratio is expected to be high between the fundamental signal and 2H frequencies at high MI. Our aim was to elucidate the efficacy of a new imaging method using an in-between frequency, denoted as 1.5 harmonic (1.5H) imaging.Methods. Six open-chest dogs were examined using Toshiba APLIO with 1.5H and conventional 2H system. The transmitting/receiving frequencies were 2.3/3.3 MHz for 1.5H and 1.4/2.8MHz for 2H imaging, respectively. Intermittent MCE was performed at a MI of 1.6 after injection of Levovist®, and baseline intensity and peak intensity of opacification of the ventricular septum were measured.Results. While baseline intensity of the septum was significantly lower using 1.5H than 2H (26±4 vs. 43±14 gray level, p<0.001), the opacification after Levovist was significantly higher using 1.5H than 2H (91±32 vs. 51±38, p<0.001). Due to the combination of these effects, visual recognition of myocardial opacification was quite superior with 1.5H imaging.Conclusion. The 1.5H imaging system provides superb contrast opacification when using high MI.

Key concepts: Second-harmonic imaging microscopy, Medicine, Mechanical index, Microbubbles, Ultrasound, Intensity (physics), Ultrasound imaging, Contrast (vision)

Related papers

Back to paper searchBrowse research topicsOriginal source
Efficacy of 1.5 Harmonic Imaging for Intravenous Myocardial Contrast Echocardiography — Research Paper | ScholarLens