1993Physica ScriptaRequires access

The Stockholm–Mainz ion trap project

I. Bergström, H Borgenstrand, Carsten Carlberg, G. Rouleau, R. Schuch, Brian Smith, G. Bollen, R. Jertz, H-J Kluge, E. Schark, Thomas Schwarz

Open publisher page 12 citations

Abstract

A new ion trap facility is described which is dedicated to studies of highly charged ions in a Penning trap. Such a trap will be connected to sources of highly charged ions, in particular the electron beam ion source CRYSIS, at the Manne Siegbahn Institute for Physics. The use of highly charged ions in a Penning trap increases the cyclotron frequency with a factor proportional to the charge which leads to a higher resolution. Also, the possibility to vary the charge state makes it possible to search for and identify different systematic effects. Thus, a substantial increase in accuracy can be expected. In addition, the combination of high charge state ions and a Penning trap allows new applications where one can take advantage of the controlled measuring situation, long observation time and high resolution detection. The initial priority will be given to high precision mass measurements of heavy stable ions. At a future stage, plans are to extend the use to other applications, such as charge exchange processes between neutrals and stored charged ions, electron impact ionization and exposure of clusters and molecules to highly charged ions as well as lifetime determinations of molecules and clusters.

About this research paper

What this paper is about

A new ion trap facility is described which is dedicated to studies of highly charged ions in a Penning trap. Such a trap will be connected to sources of highly charged ions, in particular the electron beam ion source CRYSIS, at the Manne Siegbahn Institute for Physics. The use of highly charged ions in a Penning trap increases the cyclotron frequency with a factor proportional to the charge which leads to a higher resolution. Also, the possibility to vary the charge state makes it possible to search for and identify different systematic effects. Thus, a substantial increase in accuracy can be expected. In addition, the combination of high charge state ions and a Penning trap allows new applications where one can take advantage of the controlled measuring situation, long observation time and high resolution detection. The initial priority will be given to high precision mass measurements of heavy stable ions. At a future stage, plans are to extend the use to other applications, such as charge exchange processes between neutrals and stored charged ions, electron impact ionization and exposure of clusters and molecules to highly charged ions as well as lifetime determinations of molecules and clusters.

Why it matters

OpenAlex reports 12 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A new ion trap facility is described which is dedicated to studies of highly charged ions in a Penning trap. Such a trap will be connected to sources of highly charged ions, in particular the electron beam ion source CRYSIS, at the Manne Siegbahn Institute for Physics. The use of highly charged ions in a Penning trap increases the cyclotron frequency with a factor proportional to the charge which leads to a higher resolution. Also, the possibility to vary the charge state makes it possible to search for and identify different systematic effects. Thus, a substantial increase in accuracy can be expected. In addition, the combination of high charge state ions and a Penning trap allows new applications where one can take advantage of the controlled measuring situation, long observation time and high resolution detection. The initial priority will be given to high precision mass measurements of heavy stable ions. At a future stage, plans are to extend the use to other applications, such as charge exchange processes between neutrals and stored charged ions, electron impact ionization and exposure of clusters and molecules to highly charged ions as well as lifetime determinations of molecules and clusters.

Key concepts: Penning trap, Ion, Electron beam ion trap, Ion trap, Atomic physics, Cyclotron, Physics, Ionization

Related papers

Back to paper searchBrowse research topicsOriginal source
The Stockholm–Mainz ion trap project — Research Paper | ScholarLens