2011Applied Mechanics and MaterialsOpen access

An Experimental Study on Fire Resistance of Slim Floor Beam

Hyung Jun Kim, Heung-Youl Kim, Soo Young Park

Open full text 10 citations

Abstract

Composite beam using asymmetric H-shaped steel is one of the constructional structures developed in the advanced countries in Europe since early 1990s. The purpose of this study on composite beams where H-shaped steel is partially laid in concrete slabs was to find how to design fire protection and improve fire-resistance to make deep deck plates provide the beams with advantages upon a fire and to improve stiffness in structural aspect. Only lower flange which is directly exposed to a fire was included in fire-resistance design in order to decide optimal fire- protection design condition and test was conducted for spray-coating and paint-coating. In the fire resistance test, web thickness and lower flange thickness were varied to derive the optimum condition for improving fire-resistance performance. It was observed from the test that 90-minute-protection employed to lower flange provided fire resistance for 3 hours. It was also observed that the basic shape resisted fire for 89 minutes, while web reinforcement and lower flange reinforcement provided fire-resistance for 112 and 157 minutes, respectively. The result showed that lower flange reinforcement is the most effective way to improve fire-resistance.

About this research paper

What this paper is about

Composite beam using asymmetric H-shaped steel is one of the constructional structures developed in the advanced countries in Europe since early 1990s. The purpose of this study on composite beams where H-shaped steel is partially laid in concrete slabs was to find how to design fire protection and improve fire-resistance to make deep deck plates provide the beams with advantages upon a fire and to improve stiffness in structural aspect. Only lower flange which is directly exposed to a fire was included in fire-resistance design in order to decide optimal fire- protection design condition and test was conducted for spray-coating and paint-coating. In the fire resistance test, web thickness and lower flange thickness were varied to derive the optimum condition for improving fire-resistance performance. It was observed from the test that 90-minute-protection employed to lower flange provided fire resistance for 3 hours. It was also observed that the basic shape resisted fire for 89 minutes, while web reinforcement and lower flange reinforcement provided fire-resistance for 112 and 157 minutes, respectively. The result showed that lower flange reinforcement is the most effective way to improve fire-resistance.

Why it matters

OpenAlex reports 10 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Composite beam using asymmetric H-shaped steel is one of the constructional structures developed in the advanced countries in Europe since early 1990s. The purpose of this study on composite beams where H-shaped steel is partially laid in concrete slabs was to find how to design fire protection and improve fire-resistance to make deep deck plates provide the beams with advantages upon a fire and to improve stiffness in structural aspect. Only lower flange which is directly exposed to a fire was included in fire-resistance design in order to decide optimal fire- protection design condition and test was conducted for spray-coating and paint-coating. In the fire resistance test, web thickness and lower flange thickness were varied to derive the optimum condition for improving fire-resistance performance. It was observed from the test that 90-minute-protection employed to lower flange provided fire resistance for 3 hours. It was also observed that the basic shape resisted fire for 89 minutes, while web reinforcement and lower flange reinforcement provided fire-resistance for 112 and 157 minutes, respectively. The result showed that lower flange reinforcement is the most effective way to improve fire-resistance.

Key concepts: Flange, Structural engineering, Deck, Fire resistance, Beam (structure), Stiffness, Fire test, Reinforcement

Related papers

Back to paper searchBrowse research topicsOriginal source
An Experimental Study on Fire Resistance of Slim Floor Beam — Research Paper | ScholarLens