1998Clinical & Experimental AllergyRequires access

Indoor factors associated with concentrations of house dust mite allergen, Der p 1, in a random sample of houses in Norwich, UK

Luczynska, Sterne, T. Christopher Bond, Azima Azima, Peter Burney

Open publisher page 68 citations

Abstract

BACKGROUND: Studies of house dust mite allergen concentrations suggest large variations both within and between homes. It is likely that different household characteristics influence allergen levels in different locations within the house. OBJECTIVES: To investigate household characteristics associated with higher concentrations of house dust mite allergen in a random sample of houses. METHODS: Information on indoor environment was obtained from 158 adults aged 20-44. Dust samples were collected from their living room floor, bedroom floor and mattress. Concentrations of Der p 1, the major allergen from the house dust mite Dermatophagoides pteronyssinus, were measured by monoclonal antibody immunoassay. Associations between mite allergen concentrations and household characteristics were examined using censored-normal regression models. Factors that were related to Der p 1 (P </= 0.2) in univariate analyses were included in multivariable regression models. RESULTS: Der p 1 was not detected in any location in 10 (6.3%) houses. Geometric mean concentrations of Der p 1 were 1.9 microg/g in living room floor dust, 1.7 microg/g in bedroom floor dust and 2.0 microg/g in mattress dust. Approximately 25% of living room floor and mattress, and over 30% of bedroom floor samples had Der p 1 concentrations greater than 10 microg/g. Household characteristics associated with Der p 1 concentrations in both living room and bedroom were floor level, extractor fan in the kitchen, and age of carpet. Living room Der p 1 concentrations were also associated with gas oven/hob, window condensation, open fires, vacuum cleaner type, smokers in the house and age of house. Bedroom Der p 1 concentrations were also associated with use of blankets and wash temperature of bedding. Mattress Der p 1 concentrations were associated with window condensation, concrete bedroom floor and age of mattress. CONCLUSION: Different household characteristics were associated with high Der p 1 concentrations in different parts of the house. These findings are relevant to design of allergen avoidance regimes or formulation of policy recommendations for reduction of disease associated with allergen exposure.

About this research paper

What this paper is about

BACKGROUND: Studies of house dust mite allergen concentrations suggest large variations both within and between homes. It is likely that different household characteristics influence allergen levels in different locations within the house. OBJECTIVES: To investigate household characteristics associated with higher concentrations of house dust mite allergen in a random sample of houses. METHODS: Information on indoor environment was obtained from 158 adults aged 20-44. Dust samples were collected from their living room floor, bedroom floor and mattress. Concentrations of Der p 1, the major allergen from the house dust mite Dermatophagoides pteronyssinus, were measured by monoclonal antibody immunoassay. Associations between mite allergen concentrations and household characteristics were examined using censored-normal regression models. Factors that were related to Der p 1 (P </= 0.2) in univariate analyses were included in multivariable regression models. RESULTS: Der p 1 was not detected in any location in 10 (6.3%) houses. Geometric mean concentrations of Der p 1 were 1.9 microg/g in living room floor dust, 1.7 microg/g in bedroom floor dust and 2.0 microg/g in mattress dust. Approximately 25% of living room floor and mattress, and over 30% of bedroom floor samples had Der p 1 concentrations greater than 10 microg/g. Household characteristics associated with Der p 1 concentrations in both living room and bedroom were floor level, extractor fan in the kitchen, and age of carpet. Living room Der p 1 concentrations were also associated with gas oven/hob, window condensation, open fires, vacuum cleaner type, smokers in the house and age of house. Bedroom Der p 1 concentrations were also associated with use of blankets and wash temperature of bedding. Mattress Der p 1 concentrations were associated with window condensation, concrete bedroom floor and age of mattress. CONCLUSION: Different household characteristics were associated with high Der p 1 concentrations in different parts of the house. These findings are relevant to design of allergen avoidance regimes or formulation of policy recommendations for reduction of disease associated with allergen exposure.

Why it matters

OpenAlex reports 68 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: Studies of house dust mite allergen concentrations suggest large variations both within and between homes. It is likely that different household characteristics influence allergen levels in different locations within the house. OBJECTIVES: To investigate household characteristics associated with higher concentrations of house dust mite allergen in a random sample of houses. METHODS: Information on indoor environment was obtained from 158 adults aged 20-44. Dust samples were collected from their living room floor, bedroom floor and mattress. Concentrations of Der p 1, the major allergen from the house dust mite Dermatophagoides pteronyssinus, were measured by monoclonal antibody immunoassay. Associations between mite allergen concentrations and household characteristics were examined using censored-normal regression models. Factors that were related to Der p 1 (P </= 0.2) in univariate analyses were included in multivariable regression models. RESULTS: Der p 1 was not detected in any location in 10 (6.3%) houses. Geometric mean concentrations of Der p 1 were 1.9 microg/g in living room floor dust, 1.7 microg/g in bedroom floor dust and 2.0 microg/g in mattress dust. Approximately 25% of living room floor and mattress, and over 30% of bedroom floor samples had Der p 1 concentrations greater than 10 microg/g. Household characteristics associated with Der p 1 concentrations in both living room and bedroom were floor level, extractor fan in the kitchen, and age of carpet. Living room Der p 1 concentrations were also associated with gas oven/hob, window condensation, open fires, vacuum cleaner type, smokers in the house and age of house. Bedroom Der p 1 concentrations were also associated with use of blankets and wash temperature of bedding. Mattress Der p 1 concentrations were associated with window condensation, concrete bedroom floor and age of mattress. CONCLUSION: Different household characteristics were associated with high Der p 1 concentrations in different parts of the house. These findings are relevant to design of allergen avoidance regimes or formulation of policy recommendations for reduction of disease associated with allergen exposure.

Key concepts: House dust mite, Allergen, Sample (material), Dust mites, Medicine, Environmental health, Immunology, Allergy

Related papers

Back to paper searchBrowse research topicsOriginal source
Indoor factors associated with concentrations of house dust mite allergen, Der p 1, in a random sample of houses in Norwich, UK — Research Paper | ScholarLens