The Validity of Power Output Recorded During Exercise Performance Tests Using a Kingcycle Air-Braked Cycle Ergometer When Compared With an SRM Powermeter
Balmer, R. R. Davison, D. A. Coleman, Bird
Abstract
Balmer, R. R. Davison, D. A. Coleman, Bird
Abstract
This study assessed the validity of power output recorded using an air-braked cycle ergometer (Kingcycle) when compared with a power measuring crankset (SRM). For part one of the study thirteen physically active subjects completed a continuous incremental exercise test (OBLA), for part two of the study twelve trained cyclists completed two tests; a maximal aerobic power test (MAP) and a 16.1 km time-trial (16.1 km TT). The following were compared; the peak power output (PPO) recorded for 1 min during MAP, the average power output for the duration of the time-trial and power output recorded during each stage of OBLA. For all tests, power output recorded using Kingcycle was significantly higher than SRM (P < 0.001). Ratio limits of agreement between SRM and Kingcycle for OBLA showed a bias (P < 0.00) of 0.90 (95%CI = 0.90-0.91) with a random error of X or / 1.07, and for PPO and 16.1 km TT ratio limits of agreement were 0.90 (95%CI = 0.88-0.92) X or / 1.07 and 0.92 (95% CI = 0.90-0.94) X or / 1.07, respectively. These data revealed that the Kingcycle ergometry system did not provide a valid measure of power output when compared with SRM.
OpenAlex reports 38 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
This study assessed the validity of power output recorded using an air-braked cycle ergometer (Kingcycle) when compared with a power measuring crankset (SRM). For part one of the study thirteen physically active subjects completed a continuous incremental exercise test (OBLA), for part two of the study twelve trained cyclists completed two tests; a maximal aerobic power test (MAP) and a 16.1 km time-trial (16.1 km TT). The following were compared; the peak power output (PPO) recorded for 1 min during MAP, the average power output for the duration of the time-trial and power output recorded during each stage of OBLA. For all tests, power output recorded using Kingcycle was significantly higher than SRM (P < 0.001). Ratio limits of agreement between SRM and Kingcycle for OBLA showed a bias (P < 0.00) of 0.90 (95%CI = 0.90-0.91) with a random error of X or / 1.07, and for PPO and 16.1 km TT ratio limits of agreement were 0.90 (95%CI = 0.88-0.92) X or / 1.07 and 0.92 (95% CI = 0.90-0.94) X or / 1.07, respectively. These data revealed that the Kingcycle ergometry system did not provide a valid measure of power output when compared with SRM.
Key concepts: Cycle ergometer, Limits of agreement, Bicycle ergometer, Time trial, Mathematics, Incremental exercise, Anaerobic exercise, Blood lactate