2000International Journal of Sports MedicineRequires access

The Validity of Power Output Recorded During Exercise Performance Tests Using a Kingcycle Air-Braked Cycle Ergometer When Compared With an SRM Powermeter

Balmer, R. R. Davison, D. A. Coleman, Bird

Open publisher page 38 citations

Abstract

This study assessed the validity of power output recorded using an air-braked cycle ergometer (Kingcycle) when compared with a power measuring crankset (SRM). For part one of the study thirteen physically active subjects completed a continuous incremental exercise test (OBLA), for part two of the study twelve trained cyclists completed two tests; a maximal aerobic power test (MAP) and a 16.1 km time-trial (16.1 km TT). The following were compared; the peak power output (PPO) recorded for 1 min during MAP, the average power output for the duration of the time-trial and power output recorded during each stage of OBLA. For all tests, power output recorded using Kingcycle was significantly higher than SRM (P < 0.001). Ratio limits of agreement between SRM and Kingcycle for OBLA showed a bias (P < 0.00) of 0.90 (95%CI = 0.90-0.91) with a random error of X or / 1.07, and for PPO and 16.1 km TT ratio limits of agreement were 0.90 (95%CI = 0.88-0.92) X or / 1.07 and 0.92 (95% CI = 0.90-0.94) X or / 1.07, respectively. These data revealed that the Kingcycle ergometry system did not provide a valid measure of power output when compared with SRM.

About this research paper

What this paper is about

This study assessed the validity of power output recorded using an air-braked cycle ergometer (Kingcycle) when compared with a power measuring crankset (SRM). For part one of the study thirteen physically active subjects completed a continuous incremental exercise test (OBLA), for part two of the study twelve trained cyclists completed two tests; a maximal aerobic power test (MAP) and a 16.1 km time-trial (16.1 km TT). The following were compared; the peak power output (PPO) recorded for 1 min during MAP, the average power output for the duration of the time-trial and power output recorded during each stage of OBLA. For all tests, power output recorded using Kingcycle was significantly higher than SRM (P < 0.001). Ratio limits of agreement between SRM and Kingcycle for OBLA showed a bias (P < 0.00) of 0.90 (95%CI = 0.90-0.91) with a random error of X or / 1.07, and for PPO and 16.1 km TT ratio limits of agreement were 0.90 (95%CI = 0.88-0.92) X or / 1.07 and 0.92 (95% CI = 0.90-0.94) X or / 1.07, respectively. These data revealed that the Kingcycle ergometry system did not provide a valid measure of power output when compared with SRM.

Why it matters

OpenAlex reports 38 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This study assessed the validity of power output recorded using an air-braked cycle ergometer (Kingcycle) when compared with a power measuring crankset (SRM). For part one of the study thirteen physically active subjects completed a continuous incremental exercise test (OBLA), for part two of the study twelve trained cyclists completed two tests; a maximal aerobic power test (MAP) and a 16.1 km time-trial (16.1 km TT). The following were compared; the peak power output (PPO) recorded for 1 min during MAP, the average power output for the duration of the time-trial and power output recorded during each stage of OBLA. For all tests, power output recorded using Kingcycle was significantly higher than SRM (P < 0.001). Ratio limits of agreement between SRM and Kingcycle for OBLA showed a bias (P < 0.00) of 0.90 (95%CI = 0.90-0.91) with a random error of X or / 1.07, and for PPO and 16.1 km TT ratio limits of agreement were 0.90 (95%CI = 0.88-0.92) X or / 1.07 and 0.92 (95% CI = 0.90-0.94) X or / 1.07, respectively. These data revealed that the Kingcycle ergometry system did not provide a valid measure of power output when compared with SRM.

Key concepts: Cycle ergometer, Limits of agreement, Bicycle ergometer, Time trial, Mathematics, Incremental exercise, Anaerobic exercise, Blood lactate

Related papers

Back to paper searchBrowse research topicsOriginal source
The Validity of Power Output Recorded During Exercise Performance Tests Using a Kingcycle Air-Braked Cycle Ergometer When Compared With an SRM Powermeter — Research Paper | ScholarLens