Effects of Solution Treatment on the Microstructure and Properties of 7003 Aluminum Alloy
Xiao Ming Chen, Ren Guo Song
Abstract
Xiao Ming Chen, Ren Guo Song
Abstract
The microstructure and properties of 7003 aluminum alloy before and after aging under various solid solution treatment parameters have been studied by electronic tensile machine, scanning electron microscopy (SEM) and energy dispersive X-ray spectrometer (EDS). It’s showed that the strength decreased while the ductility increased with raising the solid solution temperature before aging; the strength decreased and then increased while the ductility increased and then decreased with increasing the solid solution time. The strength of 7003 aluminum alloy after aging were evidently higher than those before aging, and the samples solutioned at 743 K for 70 min were of the best mechanical properties with YS=286 MPa, UTS=345 MPa, E=15.5%, which are higher than those of the original alloy by 2.1%, 1.5% and 29.1% respectively. Hence 743 K/70 min is one of the best solid solution regimes.
OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The microstructure and properties of 7003 aluminum alloy before and after aging under various solid solution treatment parameters have been studied by electronic tensile machine, scanning electron microscopy (SEM) and energy dispersive X-ray spectrometer (EDS). It’s showed that the strength decreased while the ductility increased with raising the solid solution temperature before aging; the strength decreased and then increased while the ductility increased and then decreased with increasing the solid solution time. The strength of 7003 aluminum alloy after aging were evidently higher than those before aging, and the samples solutioned at 743 K for 70 min were of the best mechanical properties with YS=286 MPa, UTS=345 MPa, E=15.5%, which are higher than those of the original alloy by 2.1%, 1.5% and 29.1% respectively. Hence 743 K/70 min is one of the best solid solution regimes.
Key concepts: Alloy, Microstructure, Materials science, Scanning electron microscope, Ductility (Earth science), Ultimate tensile strength, Solid solution, Aluminium