1981•Defense Technical Information Center (DTIC)Requires access

NATIONAL Dam Inspection Program. Pickeral Pond Dam (NDI I.D. Number PA-00755, PennDER I.D. Number 52-8), Delaware River Basin, Bushkill Creek, Pike County, Pennsylvania. Phase I INspection Report,

Bernard M Mihalcin

Open publisher page 0 citations

Abstract

Based on a visual inspection, operational history, and available engineering data, the dam is considered to be in fair condition. The size classification of the facility is intermediate and its hazard classification is considered to be high. In accordance with the recommended guidelines, the Spillway Design Flood (SDF) for the facility is the PMF (Probable Maximum Flood). Results of the hydrologic and hydraulic analysis indicate the facility will pass and/or store only about 40 percent of the PMF prior to embankment overtopping. A breach analysis indicates that failure under less than 1/2 PMF conditions could lead to increased downstream damage and potential for loss of life. Thus, based on screening criteria provided in the recommended guidelines, the spillway is considered to be seriously inadequate and the facility unsafe, non-emergency.

About this research paper

What this paper is about

Based on a visual inspection, operational history, and available engineering data, the dam is considered to be in fair condition. The size classification of the facility is intermediate and its hazard classification is considered to be high. In accordance with the recommended guidelines, the Spillway Design Flood (SDF) for the facility is the PMF (Probable Maximum Flood). Results of the hydrologic and hydraulic analysis indicate the facility will pass and/or store only about 40 percent of the PMF prior to embankment overtopping. A breach analysis indicates that failure under less than 1/2 PMF conditions could lead to increased downstream damage and potential for loss of life. Thus, based on screening criteria provided in the recommended guidelines, the spillway is considered to be seriously inadequate and the facility unsafe, non-emergency.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Based on a visual inspection, operational history, and available engineering data, the dam is considered to be in fair condition. The size classification of the facility is intermediate and its hazard classification is considered to be high. In accordance with the recommended guidelines, the Spillway Design Flood (SDF) for the facility is the PMF (Probable Maximum Flood). Results of the hydrologic and hydraulic analysis indicate the facility will pass and/or store only about 40 percent of the PMF prior to embankment overtopping. A breach analysis indicates that failure under less than 1/2 PMF conditions could lead to increased downstream damage and potential for loss of life. Thus, based on screening criteria provided in the recommended guidelines, the spillway is considered to be seriously inadequate and the facility unsafe, non-emergency.

Key concepts: Spillway, Flood myth, Dam failure, Environmental science, Levee, Flooding (psychology), Hydrology (agriculture), Civil engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
NATIONAL Dam Inspection Program. Pickeral Pond Dam (NDI I.D. Number PA-00755, PennDER I.D. Number 52-8), Delaware River Basin, Bushkill Creek, Pike County, Pennsylvania. Phase I INspection Report, — Research Paper | ScholarLens