1984•CirculationOpen access

Comparison between intracellular and extracellular direct current recordings of sinus node activity for evaluation of sinoatrial conduction time.

Ralph Haberl, Gerhard Steinbeck, Berndt Lüderitz

Open full text 17 citations

Abstract

For evaluation of sinoatrial conduction time in humans, study of extracellular direct current (DC) electrograms from the sinus node has been proposed. To validate this method, we compared transmembrane potentials from multiple sites (40 to 60, "mapping" of sinoatrial activation by microelectrode technique) and extracellular DC electrograms of the sinus node in 12 isolated rabbit atria. Sinoatrial conduction time, measured by microelectrodes and by extracellular electrograms, was essentially the same if the DC electrode was positioned over the pacemaker center (35 +/- 15 and 33 +/- 15 msec, respectively; deviation less or equal to 2 msec). While in all experiments phase 4 and phase 0 depolarization of dominant pacemaker fibers was reflected in the DC electrogram, it shape was influenced by pacemaker location and duration of sinoatrial impulse propagation. If sinoatrial conduction time was long (greater than 25 msec) the transition from the diastolic to the upstroke slope was smooth and the sinus node potential was clearly separated from atrial activity. If sinoatrial conduction time was short (less or equal to 25 msec) the onset of the upstroke slope was well defined and the upstroke slope directly merged into atrial activity. Extracellular recordings 0.2 mm away from the pacemaker center were fairly unchanged in shape; however, sinoatrial conduction time was significantly underestimated. Underestimation also occurred when the tip size of the extracellular electrode was increased from 0.2 to 0.5 and 1.0 mm. Thus sinus node activity is reflected in extracellular DC recordings; however, measurement of sinoatrial conduction time by this technique requires exact localization of the electrode over the pacemaker center, which cannot be controlled in humans.

Open-access reader

About this research paper

What this paper is about

For evaluation of sinoatrial conduction time in humans, study of extracellular direct current (DC) electrograms from the sinus node has been proposed. To validate this method, we compared transmembrane potentials from multiple sites (40 to 60, "mapping" of sinoatrial activation by microelectrode technique) and extracellular DC electrograms of the sinus node in 12 isolated rabbit atria. Sinoatrial conduction time, measured by microelectrodes and by extracellular electrograms, was essentially the same if the DC electrode was positioned over the pacemaker center (35 +/- 15 and 33 +/- 15 msec, respectively; deviation less or equal to 2 msec). While in all experiments phase 4 and phase 0 depolarization of dominant pacemaker fibers was reflected in the DC electrogram, it shape was influenced by pacemaker location and duration of sinoatrial impulse propagation. If sinoatrial conduction time was long (greater than 25 msec) the transition from the diastolic to the upstroke slope was smooth and the sinus node potential was clearly separated from atrial activity. If sinoatrial conduction time was short (less or equal to 25 msec) the onset of the upstroke slope was well defined and the upstroke slope directly merged into atrial activity. Extracellular recordings 0.2 mm away from the pacemaker center were fairly unchanged in shape; however, sinoatrial conduction time was significantly underestimated. Underestimation also occurred when the tip size of the extracellular electrode was increased from 0.2 to 0.5 and 1.0 mm. Thus sinus node activity is reflected in extracellular DC recordings; however, measurement of sinoatrial conduction time by this technique requires exact localization of the electrode over the pacemaker center, which cannot be controlled in humans.

Why it matters

OpenAlex reports 17 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

For evaluation of sinoatrial conduction time in humans, study of extracellular direct current (DC) electrograms from the sinus node has been proposed. To validate this method, we compared transmembrane potentials from multiple sites (40 to 60, "mapping" of sinoatrial activation by microelectrode technique) and extracellular DC electrograms of the sinus node in 12 isolated rabbit atria. Sinoatrial conduction time, measured by microelectrodes and by extracellular electrograms, was essentially the same if the DC electrode was positioned over the pacemaker center (35 +/- 15 and 33 +/- 15 msec, respectively; deviation less or equal to 2 msec). While in all experiments phase 4 and phase 0 depolarization of dominant pacemaker fibers was reflected in the DC electrogram, it shape was influenced by pacemaker location and duration of sinoatrial impulse propagation. If sinoatrial conduction time was long (greater than 25 msec) the transition from the diastolic to the upstroke slope was smooth and the sinus node potential was clearly separated from atrial activity. If sinoatrial conduction time was short (less or equal to 25 msec) the onset of the upstroke slope was well defined and the upstroke slope directly merged into atrial activity. Extracellular recordings 0.2 mm away from the pacemaker center were fairly unchanged in shape; however, sinoatrial conduction time was significantly underestimated. Underestimation also occurred when the tip size of the extracellular electrode was increased from 0.2 to 0.5 and 1.0 mm. Thus sinus node activity is reflected in extracellular DC recordings; however, measurement of sinoatrial conduction time by this technique requires exact localization of the electrode over the pacemaker center, which cannot be controlled in humans.

Key concepts: Sinoatrial node, Extracellular, Medicine, Electrophysiology, Depolarization, Sinus (botany), Diastolic depolarization, Cardiology

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparison between intracellular and extracellular direct current recordings of sinus node activity for evaluation of sinoatrial conduction time. — Research Paper | ScholarLens