WHOLE FLOWFIELD PARTICLE IMAGE VELOCIMETRY MEASUREMENTS IN A 10 CC PULSATILE PEDIATRIC ASSIST PUMP

Keefe B. Manning, Brandon D Wivholm, Jennifer Long, Arnold A. Fontaine, Steven Deutsch

Open publisher page 0 citations

Abstract

The analysis of a whole flowfield particle image velocimetry study of the 10 cc Penn State pulsatile pediatric ventricular assist device (PVAD) is presented. The pressures and flow through the PVAD are controlled with a mock circulatory loop. The blood analog (Sodium Iodide/Xanthan gum) solution is a good match for the viscoelastic properties of blood across the shear rate range. An earlier version of the Penn State PVAD has shown a much higher incidence of clot formation than does the adult pump from which it was derived. Therefore, a focus of the current study is on the wall shear stress. We identify regions of low wall shear stress throughout the pump cycle and suggest how the pump design might be geometrically modified to increase the flow rate there. In addition, we analyze the flow in the valve regions, as predicting the result of downsizing the valves from the adult pump is not straightforward.

About this research paper

What this paper is about

The analysis of a whole flowfield particle image velocimetry study of the 10 cc Penn State pulsatile pediatric ventricular assist device (PVAD) is presented. The pressures and flow through the PVAD are controlled with a mock circulatory loop. The blood analog (Sodium Iodide/Xanthan gum) solution is a good match for the viscoelastic properties of blood across the shear rate range. An earlier version of the Penn State PVAD has shown a much higher incidence of clot formation than does the adult pump from which it was derived. Therefore, a focus of the current study is on the wall shear stress. We identify regions of low wall shear stress throughout the pump cycle and suggest how the pump design might be geometrically modified to increase the flow rate there. In addition, we analyze the flow in the valve regions, as predicting the result of downsizing the valves from the adult pump is not straightforward.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The analysis of a whole flowfield particle image velocimetry study of the 10 cc Penn State pulsatile pediatric ventricular assist device (PVAD) is presented. The pressures and flow through the PVAD are controlled with a mock circulatory loop. The blood analog (Sodium Iodide/Xanthan gum) solution is a good match for the viscoelastic properties of blood across the shear rate range. An earlier version of the Penn State PVAD has shown a much higher incidence of clot formation than does the adult pump from which it was derived. Therefore, a focus of the current study is on the wall shear stress. We identify regions of low wall shear stress throughout the pump cycle and suggest how the pump design might be geometrically modified to increase the flow rate there. In addition, we analyze the flow in the valve regions, as predicting the result of downsizing the valves from the adult pump is not straightforward.

Key concepts: Particle image velocimetry, Pulsatile flow, Mechanics, Shear stress, Materials science, Particle tracking velocimetry, Velocimetry, Physics

Related papers

Back to paper searchBrowse research topicsOriginal source
WHOLE FLOWFIELD PARTICLE IMAGE VELOCIMETRY MEASUREMENTS IN A 10 CC PULSATILE PEDIATRIC ASSIST PUMP — Research Paper | ScholarLens