1973The Journal of the Acoustical Society of AmericaOpen access

Interdisciplinary Design Effort to Control Building Mechanical Equipment Noise

C. M. Salter, S I Rosenfeld

Open full text 0 citations

Abstract

When locating a government building complex with its requisite power generating capabilities in a very quiet residential community, extensive interaction was required between the architect, mechanical and electrical engineers, and acoustical consultant. The success of the design was dependent on achieving acoustical compatibility with the neighborhood consistent with aesthetic, legal, and budgetary considerations. This case study is presented to highlight the interdisciplinary effort necessary to satisfy the various constraints imposed by the community, client, and designers. The maximum noise-level criterion established for the mechanical and electrical equipment was based on the existing ambient, and guidelines contained in U. S. Army Manuals TM 5-805-4 and TM 5-805-9. The noise levels of the air-cooled chillers, transformer, and engine-generator, all located in an outdoor equipment yard, were estimated using procedures elucidated in the Army manuals. This information was augmented by acoustic field measurements of similar equipment, plus manufacturers' SPL and power-level data. The noise-control treatments required to achieve the aforementioned acoustic criterion and their individual costs are discussed along with a description of the engineering modifications to the equipment.

Open-access reader

About this research paper

What this paper is about

When locating a government building complex with its requisite power generating capabilities in a very quiet residential community, extensive interaction was required between the architect, mechanical and electrical engineers, and acoustical consultant. The success of the design was dependent on achieving acoustical compatibility with the neighborhood consistent with aesthetic, legal, and budgetary considerations. This case study is presented to highlight the interdisciplinary effort necessary to satisfy the various constraints imposed by the community, client, and designers. The maximum noise-level criterion established for the mechanical and electrical equipment was based on the existing ambient, and guidelines contained in U. S. Army Manuals TM 5-805-4 and TM 5-805-9. The noise levels of the air-cooled chillers, transformer, and engine-generator, all located in an outdoor equipment yard, were estimated using procedures elucidated in the Army manuals. This information was augmented by acoustic field measurements of similar equipment, plus manufacturers' SPL and power-level data. The noise-control treatments required to achieve the aforementioned acoustic criterion and their individual costs are discussed along with a description of the engineering modifications to the equipment.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

When locating a government building complex with its requisite power generating capabilities in a very quiet residential community, extensive interaction was required between the architect, mechanical and electrical engineers, and acoustical consultant. The success of the design was dependent on achieving acoustical compatibility with the neighborhood consistent with aesthetic, legal, and budgetary considerations. This case study is presented to highlight the interdisciplinary effort necessary to satisfy the various constraints imposed by the community, client, and designers. The maximum noise-level criterion established for the mechanical and electrical equipment was based on the existing ambient, and guidelines contained in U. S. Army Manuals TM 5-805-4 and TM 5-805-9. The noise levels of the air-cooled chillers, transformer, and engine-generator, all located in an outdoor equipment yard, were estimated using procedures elucidated in the Army manuals. This information was augmented by acoustic field measurements of similar equipment, plus manufacturers' SPL and power-level data. The noise-control treatments required to achieve the aforementioned acoustic criterion and their individual costs are discussed along with a description of the engineering modifications to the equipment.

Key concepts: Computer science, Noise control, Transformer, Noise (video), Chiller, Design engineer, QUIET, Automotive engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Interdisciplinary Design Effort to Control Building Mechanical Equipment Noise — Research Paper | ScholarLens