2009Rapid Communications in Mass SpectrometryRequires access

G‐SIMS: relative effectiveness of different monatomic primary ion source combinations

M. P. Seah, Ian S. Gilmore, Felicia M. Green

Open publisher page 7 citations

Abstract

An analysis is made of the characteristics of monatomic primary ion sources to generate G-SIMS (gentle SIMS) spectra. In previous studies, this is resolved into the parameter beta that describes the relative intensities of ions in the series C(n)H(n+2-i) as i changes. For this, data from polystyrene are most extensive. It is found that the experimental beta values, which relate to the emitted secondary ion fragment surface plasma temperatures, are accurately described by an empirical fit involving the ratio of the sputtering yield and the mass of the primary ion. This description covers data for Ar(+), Bi(+), Cs(+), Ga(+), Mn(+) and Xe(+) monatomic primary ions with energies in the range 4 to 25 keV, placing them in a coherent framework, and permits the performance of any other monatomic primary ion to be predicted. This shows that, of all monatomic primary ions, Bi will yield the highest beta values and Mn the lowest. Since the G-SIMS spectra are ratios, a ratio involving spectra using these primary ions gives the maximum signal quality possible and these are therefore recommended for use. The previous choice of these ions for a combined G-SIMS source, based on practical considerations, is thus shown to be optimum.

About this research paper

What this paper is about

An analysis is made of the characteristics of monatomic primary ion sources to generate G-SIMS (gentle SIMS) spectra. In previous studies, this is resolved into the parameter beta that describes the relative intensities of ions in the series C(n)H(n+2-i) as i changes. For this, data from polystyrene are most extensive. It is found that the experimental beta values, which relate to the emitted secondary ion fragment surface plasma temperatures, are accurately described by an empirical fit involving the ratio of the sputtering yield and the mass of the primary ion. This description covers data for Ar(+), Bi(+), Cs(+), Ga(+), Mn(+) and Xe(+) monatomic primary ions with energies in the range 4 to 25 keV, placing them in a coherent framework, and permits the performance of any other monatomic primary ion to be predicted. This shows that, of all monatomic primary ions, Bi will yield the highest beta values and Mn the lowest. Since the G-SIMS spectra are ratios, a ratio involving spectra using these primary ions gives the maximum signal quality possible and these are therefore recommended for use. The previous choice of these ions for a combined G-SIMS source, based on practical considerations, is thus shown to be optimum.

Why it matters

OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

An analysis is made of the characteristics of monatomic primary ion sources to generate G-SIMS (gentle SIMS) spectra. In previous studies, this is resolved into the parameter beta that describes the relative intensities of ions in the series C(n)H(n+2-i) as i changes. For this, data from polystyrene are most extensive. It is found that the experimental beta values, which relate to the emitted secondary ion fragment surface plasma temperatures, are accurately described by an empirical fit involving the ratio of the sputtering yield and the mass of the primary ion. This description covers data for Ar(+), Bi(+), Cs(+), Ga(+), Mn(+) and Xe(+) monatomic primary ions with energies in the range 4 to 25 keV, placing them in a coherent framework, and permits the performance of any other monatomic primary ion to be predicted. This shows that, of all monatomic primary ions, Bi will yield the highest beta values and Mn the lowest. Since the G-SIMS spectra are ratios, a ratio involving spectra using these primary ions gives the maximum signal quality possible and these are therefore recommended for use. The previous choice of these ions for a combined G-SIMS source, based on practical considerations, is thus shown to be optimum.

Key concepts: Monatomic ion, Chemistry, Ion, Yield (engineering), Spectral line, Sputtering, Static secondary-ion mass spectrometry, Analytical Chemistry (journal)

Related papers

Back to paper searchBrowse research topicsOriginal source
G‐SIMS: relative effectiveness of different monatomic primary ion source combinations — Research Paper | ScholarLens