2013Advanced materials researchOpen access

Reoxygenation Rate for Airlift Inner Circulation Reactor

Ke Pi, Min Xia, Shi Shi, Xiao Qu

Open full text 0 citations

Abstract

Airlift inner circulation reactor (AICR) consisting of beaker and built-in aeration tank was introduced in this paper. The Dissolved oxygen recovery (RDO) was highly influenced by the ratios of the height of built-in aeration tank to the height of liquid level in reactor (Rh/H), the diameter of built-in aeration tank to the diameter of the reactor (Rd/D) and aeration rate (QN). Average RDO of 24.25 m.gm-3.s-s and DO concentration of 8.97mg.l-1 were obtained at Rd/D=0.47, Rh/H=0.68 and QN =1.0m3.m-3.min-1 for aerating 370s at 17°C. The total transferred oxygen in 4L deoxidized water reached 35.89mg, which had an increase by 11.15% than that of the traditional airlift reactor (AR). The DO concentration was 88.33-9.34mg.l-1 for AICR, but it’s only 7.71-8.58mg.l-1 for AR.

About this research paper

What this paper is about

Airlift inner circulation reactor (AICR) consisting of beaker and built-in aeration tank was introduced in this paper. The Dissolved oxygen recovery (RDO) was highly influenced by the ratios of the height of built-in aeration tank to the height of liquid level in reactor (Rh/H), the diameter of built-in aeration tank to the diameter of the reactor (Rd/D) and aeration rate (QN). Average RDO of 24.25 m.gm-3.s-s and DO concentration of 8.97mg.l-1 were obtained at Rd/D=0.47, Rh/H=0.68 and QN =1.0m3.m-3.min-1 for aerating 370s at 17°C. The total transferred oxygen in 4L deoxidized water reached 35.89mg, which had an increase by 11.15% than that of the traditional airlift reactor (AR). The DO concentration was 88.33-9.34mg.l-1 for AICR, but it’s only 7.71-8.58mg.l-1 for AR.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Airlift inner circulation reactor (AICR) consisting of beaker and built-in aeration tank was introduced in this paper. The Dissolved oxygen recovery (RDO) was highly influenced by the ratios of the height of built-in aeration tank to the height of liquid level in reactor (Rh/H), the diameter of built-in aeration tank to the diameter of the reactor (Rd/D) and aeration rate (QN). Average RDO of 24.25 m.gm-3.s-s and DO concentration of 8.97mg.l-1 were obtained at Rd/D=0.47, Rh/H=0.68 and QN =1.0m3.m-3.min-1 for aerating 370s at 17°C. The total transferred oxygen in 4L deoxidized water reached 35.89mg, which had an increase by 11.15% than that of the traditional airlift reactor (AR). The DO concentration was 88.33-9.34mg.l-1 for AICR, but it’s only 7.71-8.58mg.l-1 for AR.

Key concepts: Aeration, Airlift, Oxygen, Bioreactor, Chemistry, Environmental engineering, Circulation (fluid dynamics), Chromatography

Related papers

Back to paper searchBrowse research topicsOriginal source
Reoxygenation Rate for Airlift Inner Circulation Reactor — Research Paper | ScholarLens