Electromyography of the internal anal sphincter performed under endosonographic guidance description of a new method
Michael Sørensen, Michael Bachmann Nielsen, Jan Fog Pedersen, John Christiansen
Abstract
Michael Sørensen, Michael Bachmann Nielsen, Jan Fog Pedersen, John Christiansen
Abstract
PURPOSE: The aim of our study was to investigate internal anal sphincter electromyographic signals. METHODS: Electromyography of the internal anal sphincter was performed with platinum wire electrodes in six healthy volunteers (three males and three females), inserted under endosonographic guidance. Platinum wire electrodes were also inserted into the external anal sphincter. Activity of both the internal and external and sphincter in a 40-second period was measured. RESULTS: Internal anal sphincter median activity was 22.1 (range, 5.5-67.6) microV. Slow-wave activity was 47 cycles/minute (range, 34-55 cycles/minute). After inflation of a rectal balloon with air until a constant relaxation of the anal canal was obtained, a decrease in internal and sphincter activity to 15.9 (1.2-31.3) microV as well as a decrease in slow-wave activity to 34 cycles/minute (range, 27-40 cycles/minute) was found. The original internal anal sphincter EMG was resumed after deflation of the rectal balloon. External anal sphincter median activity was 3.1 (range, 0.77-18.6) microV. During inflation of the rectal balloon, a reflex increase in external sphincter EMG activity was found. With the rectal balloon fully inflated a part of this increase was still present, 11.0 (1.9-24.6) microV. In some of the subjects, this increased activity was superimposed on the internal anal sphincter recordings as well. During a voluntary squeeze it was not possible to identify internal anal sphincter activity due to activity of the external anal sphincter totally overriding the internal anal sphincter signal. CONCLUSION: Precise EMG recordings from the internal anal sphincter is possible with endosonographic guidance of the electrodes, except during voluntary squeezing of the external and sphincter.
OpenAlex reports 19 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
PURPOSE: The aim of our study was to investigate internal anal sphincter electromyographic signals. METHODS: Electromyography of the internal anal sphincter was performed with platinum wire electrodes in six healthy volunteers (three males and three females), inserted under endosonographic guidance. Platinum wire electrodes were also inserted into the external anal sphincter. Activity of both the internal and external and sphincter in a 40-second period was measured. RESULTS: Internal anal sphincter median activity was 22.1 (range, 5.5-67.6) microV. Slow-wave activity was 47 cycles/minute (range, 34-55 cycles/minute). After inflation of a rectal balloon with air until a constant relaxation of the anal canal was obtained, a decrease in internal and sphincter activity to 15.9 (1.2-31.3) microV as well as a decrease in slow-wave activity to 34 cycles/minute (range, 27-40 cycles/minute) was found. The original internal anal sphincter EMG was resumed after deflation of the rectal balloon. External anal sphincter median activity was 3.1 (range, 0.77-18.6) microV. During inflation of the rectal balloon, a reflex increase in external sphincter EMG activity was found. With the rectal balloon fully inflated a part of this increase was still present, 11.0 (1.9-24.6) microV. In some of the subjects, this increased activity was superimposed on the internal anal sphincter recordings as well. During a voluntary squeeze it was not possible to identify internal anal sphincter activity due to activity of the external anal sphincter totally overriding the internal anal sphincter signal. CONCLUSION: Precise EMG recordings from the internal anal sphincter is possible with endosonographic guidance of the electrodes, except during voluntary squeezing of the external and sphincter.
Key concepts: Internal anal sphincter, External anal sphincter, Medicine, Electromyography, Urethral sphincter, Anal canal, Sphincter, Balloon