1986•IEEE Transactions on Energy ConversionRequires access

Impulse Strength of High Voltage Motor Coil Turn Insulation

Bal Krishen Gupta, M. Kurtz, Greg C. Stone, D.K. Sharma

Open publisher page 14 citations

Abstract

Breakdown of the turn insulation in large ac motors eventually leads to the failure of the stator winding. The turn insulation can fail if the motor coils are subjected to steep-fronted surges. The impulse strength of the turn insulation was determined for fifty-three typical coils procured from different manufacturers and tested singly in air. The coils had six different insulation systems and their specifications (voltage, power, size, turns, strands etc) cover a very wide range. Most coils were found to have an impulse strength exceeding 5 times peak line-to-ground voltage (5 pu).

About this research paper

What this paper is about

Breakdown of the turn insulation in large ac motors eventually leads to the failure of the stator winding. The turn insulation can fail if the motor coils are subjected to steep-fronted surges. The impulse strength of the turn insulation was determined for fifty-three typical coils procured from different manufacturers and tested singly in air. The coils had six different insulation systems and their specifications (voltage, power, size, turns, strands etc) cover a very wide range. Most coils were found to have an impulse strength exceeding 5 times peak line-to-ground voltage (5 pu).

Why it matters

OpenAlex reports 14 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Breakdown of the turn insulation in large ac motors eventually leads to the failure of the stator winding. The turn insulation can fail if the motor coils are subjected to steep-fronted surges. The impulse strength of the turn insulation was determined for fifty-three typical coils procured from different manufacturers and tested singly in air. The coils had six different insulation systems and their specifications (voltage, power, size, turns, strands etc) cover a very wide range. Most coils were found to have an impulse strength exceeding 5 times peak line-to-ground voltage (5 pu).

Key concepts: Impulse (physics), Electromagnetic coil, Stator, Electrical engineering, Voltage, Surge, Materials science, Insulation system