An Electrogenerated Chemiluminescence Probe and Its Application Utilizing Tris(2,2‘-bipyridyl)ruthenium(II) and Luminol Chemiluminescence without a Flowing Stream
Jacqueline Preston, Timothy A. Nieman
Abstract
Jacqueline Preston, Timothy A. Nieman
Abstract
A novel electrogenerated chemiluminescent (ECL) probe that does not require a dark box to exclude ambient light has been developed. The probe is placed within the sample solution in a fashion similar to the use of a pH electrode. Thus, the flowing stream method of analyte introduction typically used for ECL analysis is not necessary. A fiber-optic bundle is utilized to carry the light produced within the probe to a photomultiplier tube for detection. Within the body of this probe is a three-electrode configuration necessary for ECL generation. The three ECL systems, luminol, tris(2,2‘-bipyridyl)ruthenium(III), and luminol coupled with an immobilized oxidase enzyme, have been used with this probe. The relative standard deviation for a typical sample was found to be 0.6%. Glucose determinations ranging from 3.0 to 1000 μM were made without a pH change for several real samples employing luminol and glucose oxidase immobilized within the probe body.
OpenAlex reports 33 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A novel electrogenerated chemiluminescent (ECL) probe that does not require a dark box to exclude ambient light has been developed. The probe is placed within the sample solution in a fashion similar to the use of a pH electrode. Thus, the flowing stream method of analyte introduction typically used for ECL analysis is not necessary. A fiber-optic bundle is utilized to carry the light produced within the probe to a photomultiplier tube for detection. Within the body of this probe is a three-electrode configuration necessary for ECL generation. The three ECL systems, luminol, tris(2,2‘-bipyridyl)ruthenium(III), and luminol coupled with an immobilized oxidase enzyme, have been used with this probe. The relative standard deviation for a typical sample was found to be 0.6%. Glucose determinations ranging from 3.0 to 1000 μM were made without a pH change for several real samples employing luminol and glucose oxidase immobilized within the probe body.
Key concepts: Chemiluminescence, Luminol, Chemistry, Ruthenium, Glucose oxidase, Analyte, Electrochemiluminescence, Tris