The fatigue behavior of a high strength steel 300 M in the gigacycle regime was investigated. Fully reversed tension — compression fatigue tests at ambient temperature were performed using an ultrasonic fatigue system operating at 20 kHz. The staircase test method was employed to obtain accurate values of the mean fatigue strength corresponding to fixed numbers of cycles up to 109. These results were compared to the curve which is estimated by the data tested in the mid-long life regime on conventional servo hydraulic test machine at 20 Hz. Results indicate that the fatigue strength determined from ultrasonic fatigue testing is lightly higher than conventional testing in the range of 106–107 cycles. It is obvious that nucleations of fractures tend to occur below the surface, if fractures happen after more than 107 cycles. All the fractured specimens fails from internal SiO2 inclusions or smaller carbides and carbide clusters.
OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The fatigue behavior of a high strength steel 300 M in the gigacycle regime was investigated. Fully reversed tension — compression fatigue tests at ambient temperature were performed using an ultrasonic fatigue system operating at 20 kHz. The staircase test method was employed to obtain accurate values of the mean fatigue strength corresponding to fixed numbers of cycles up to 109. These results were compared to the curve which is estimated by the data tested in the mid-long life regime on conventional servo hydraulic test machine at 20 Hz. Results indicate that the fatigue strength determined from ultrasonic fatigue testing is lightly higher than conventional testing in the range of 106–107 cycles. It is obvious that nucleations of fractures tend to occur below the surface, if fractures happen after more than 107 cycles. All the fractured specimens fails from internal SiO2 inclusions or smaller carbides and carbide clusters.
Key concepts: Materials science, Carbide, Fatigue limit, Ultrasonic sensor, Ultrasonic testing, Fatigue testing, Structural engineering, Compression (physics)