2008Journal of Nuclear Science and TechnologyOpen access

A Method of Calibration for Measurement of Low Level Tritium in Environmental Water using a Liquid Scintillation Counter

Satoshi Fukutani, Masami Fukui, Akio Kôyama, Kenzo Nishimaki

Open full text 6 citations

Abstract

When low levels of tritium are measured in water, quantifying and removing the background reading caused by other influences is very important. A liquid scintillation counter (LSC) and tritium-free water are most commonly used for measuring tritium and estimating the background caused by various sources. Tritium-free water is difficult to obtain and maintain, and developing a method for estimating the background without using tritium-free water is an important contribution. This study establishes such a method using a tritium enrichment operation on tritiated water samples which have several concentration levels. Because the value measured by the LSC is composed of the tritium signal and the background, an enrichment operation will only increase the tritium radiation signal. On this premise, tritiated water samples with several levels of tritium activity were enriched and used to quantify the background statistically.

Open-access reader

About this research paper

What this paper is about

When low levels of tritium are measured in water, quantifying and removing the background reading caused by other influences is very important. A liquid scintillation counter (LSC) and tritium-free water are most commonly used for measuring tritium and estimating the background caused by various sources. Tritium-free water is difficult to obtain and maintain, and developing a method for estimating the background without using tritium-free water is an important contribution. This study establishes such a method using a tritium enrichment operation on tritiated water samples which have several concentration levels. Because the value measured by the LSC is composed of the tritium signal and the background, an enrichment operation will only increase the tritium radiation signal. On this premise, tritiated water samples with several levels of tritium activity were enriched and used to quantify the background statistically.

Why it matters

OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

When low levels of tritium are measured in water, quantifying and removing the background reading caused by other influences is very important. A liquid scintillation counter (LSC) and tritium-free water are most commonly used for measuring tritium and estimating the background caused by various sources. Tritium-free water is difficult to obtain and maintain, and developing a method for estimating the background without using tritium-free water is an important contribution. This study establishes such a method using a tritium enrichment operation on tritiated water samples which have several concentration levels. Because the value measured by the LSC is composed of the tritium signal and the background, an enrichment operation will only increase the tritium radiation signal. On this premise, tritiated water samples with several levels of tritium activity were enriched and used to quantify the background statistically.

Key concepts: Tritium, Tritiated water, Liquid scintillation counting, Radiochemistry, Scintillation counter, Chemistry, Calibration, Environmental science

Related papers

Back to paper searchBrowse research topicsOriginal source
A Method of Calibration for Measurement of Low Level Tritium in Environmental Water using a Liquid Scintillation Counter — Research Paper | ScholarLens