A Method of Calibration for Measurement of Low Level Tritium in Environmental Water using a Liquid Scintillation Counter
Satoshi Fukutani, Masami Fukui, Akio Kôyama, Kenzo Nishimaki
Abstract
Open-access reader
Satoshi Fukutani, Masami Fukui, Akio Kôyama, Kenzo Nishimaki
Abstract
Open-access reader
When low levels of tritium are measured in water, quantifying and removing the background reading caused by other influences is very important. A liquid scintillation counter (LSC) and tritium-free water are most commonly used for measuring tritium and estimating the background caused by various sources. Tritium-free water is difficult to obtain and maintain, and developing a method for estimating the background without using tritium-free water is an important contribution. This study establishes such a method using a tritium enrichment operation on tritiated water samples which have several concentration levels. Because the value measured by the LSC is composed of the tritium signal and the background, an enrichment operation will only increase the tritium radiation signal. On this premise, tritiated water samples with several levels of tritium activity were enriched and used to quantify the background statistically.
OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
When low levels of tritium are measured in water, quantifying and removing the background reading caused by other influences is very important. A liquid scintillation counter (LSC) and tritium-free water are most commonly used for measuring tritium and estimating the background caused by various sources. Tritium-free water is difficult to obtain and maintain, and developing a method for estimating the background without using tritium-free water is an important contribution. This study establishes such a method using a tritium enrichment operation on tritiated water samples which have several concentration levels. Because the value measured by the LSC is composed of the tritium signal and the background, an enrichment operation will only increase the tritium radiation signal. On this premise, tritiated water samples with several levels of tritium activity were enriched and used to quantify the background statistically.
Key concepts: Tritium, Tritiated water, Liquid scintillation counting, Radiochemistry, Scintillation counter, Chemistry, Calibration, Environmental science