2004•Journal of Paediatrics and Child HealthRequires access

Measurement of resting energy expenditure in infants

Julie E. Bines, Helen Truby

Open publisher page 9 citations

Abstract

OBJECTIVE: The method for measurement of basal metabolic rate (BMR) using indirect calorimetry in adults is well established but is impractical in infants. METHODS: In this prospective study energy expenditure was measured using indirect calorimetry in 14 infants when sleeping and when lying quietly awake. RESULTS: Sleeping metabolic rate (SMR) was lower than energy expenditure (EE) measured in the same infants in a quiet resting state (mean difference [SD]: 297 [162] kJ/d; P < 0.005; 55 [33.4] kJ/kg per day; P < 0.005). The correlation within individuals suggests that these differences are related to the level of arousal. Awake EE, but not SMR, was significantly greater than estimated BMR using the FAO/WHO/UNU predictive equation. CONCLUSIONS: In infants, the level of arousal during measurement of EE can significantly impact on the interpretation of EE results. A standardized method for the measurement of EE in infants using indirect calorimetry is proposed.

About this research paper

What this paper is about

OBJECTIVE: The method for measurement of basal metabolic rate (BMR) using indirect calorimetry in adults is well established but is impractical in infants. METHODS: In this prospective study energy expenditure was measured using indirect calorimetry in 14 infants when sleeping and when lying quietly awake. RESULTS: Sleeping metabolic rate (SMR) was lower than energy expenditure (EE) measured in the same infants in a quiet resting state (mean difference [SD]: 297 [162] kJ/d; P < 0.005; 55 [33.4] kJ/kg per day; P < 0.005). The correlation within individuals suggests that these differences are related to the level of arousal. Awake EE, but not SMR, was significantly greater than estimated BMR using the FAO/WHO/UNU predictive equation. CONCLUSIONS: In infants, the level of arousal during measurement of EE can significantly impact on the interpretation of EE results. A standardized method for the measurement of EE in infants using indirect calorimetry is proposed.

Why it matters

OpenAlex reports 9 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: The method for measurement of basal metabolic rate (BMR) using indirect calorimetry in adults is well established but is impractical in infants. METHODS: In this prospective study energy expenditure was measured using indirect calorimetry in 14 infants when sleeping and when lying quietly awake. RESULTS: Sleeping metabolic rate (SMR) was lower than energy expenditure (EE) measured in the same infants in a quiet resting state (mean difference [SD]: 297 [162] kJ/d; P < 0.005; 55 [33.4] kJ/kg per day; P < 0.005). The correlation within individuals suggests that these differences are related to the level of arousal. Awake EE, but not SMR, was significantly greater than estimated BMR using the FAO/WHO/UNU predictive equation. CONCLUSIONS: In infants, the level of arousal during measurement of EE can significantly impact on the interpretation of EE results. A standardized method for the measurement of EE in infants using indirect calorimetry is proposed.

Key concepts: Basal metabolic rate, Medicine, Resting energy expenditure, Energy expenditure, Calorimetry, Limits of agreement, Animal science, Pediatrics