Normal conducting transfer coil for SQUID NDE
Tadayuki Kondo, Hideo Itozaki
Abstract
Open-access reader
Tadayuki Kondo, Hideo Itozaki
Abstract
Open-access reader
We have investigated the performance of a normal conducting transfer coil (n-coil) for nondestructive evaluation with a SQUID. The transfer efficiency, which depends on frequency and wire impedance, has been calculated for several coil designs to determine the performance of the n-coil. We have fabricated a 30 mm diameter n-coil and examined its performance with a high- T C SQUID. If both the pick-up coil and the input coil have 50 turns, then at high frequencies the magnetic field produced by the input coil becomes 50% of the magnetic field at the pick-up coil, with a low cut-off frequency of 2 kHz. The experimental result agrees well with a numerical calculation, which suggests a magnitude of magnetic field detected by our SQUID equal to the magnitude of the quasi-uniform magnetic field produced by the input coil. We also confirmed that the thermal noise of the n-coil, produced by its normal resistance, does not become higher than the intrinsic magnetic field noise of the SQUID.
OpenAlex reports 17 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
We have investigated the performance of a normal conducting transfer coil (n-coil) for nondestructive evaluation with a SQUID. The transfer efficiency, which depends on frequency and wire impedance, has been calculated for several coil designs to determine the performance of the n-coil. We have fabricated a 30 mm diameter n-coil and examined its performance with a high- T C SQUID. If both the pick-up coil and the input coil have 50 turns, then at high frequencies the magnetic field produced by the input coil becomes 50% of the magnetic field at the pick-up coil, with a low cut-off frequency of 2 kHz. The experimental result agrees well with a numerical calculation, which suggests a magnitude of magnetic field detected by our SQUID equal to the magnitude of the quasi-uniform magnetic field produced by the input coil. We also confirmed that the thermal noise of the n-coil, produced by its normal resistance, does not become higher than the intrinsic magnetic field noise of the SQUID.
Key concepts: Electromagnetic coil, Coil noise, Squid, Search coil, Nuclear magnetic resonance, Magnetic field, Materials science, Acoustics