2004Superconductor Science and TechnologyOpen access

Normal conducting transfer coil for SQUID NDE

Tadayuki Kondo, Hideo Itozaki

Open full text 17 citations

Abstract

We have investigated the performance of a normal conducting transfer coil (n-coil) for nondestructive evaluation with a SQUID. The transfer efficiency, which depends on frequency and wire impedance, has been calculated for several coil designs to determine the performance of the n-coil. We have fabricated a 30 mm diameter n-coil and examined its performance with a high- T C SQUID. If both the pick-up coil and the input coil have 50 turns, then at high frequencies the magnetic field produced by the input coil becomes 50% of the magnetic field at the pick-up coil, with a low cut-off frequency of 2 kHz. The experimental result agrees well with a numerical calculation, which suggests a magnitude of magnetic field detected by our SQUID equal to the magnitude of the quasi-uniform magnetic field produced by the input coil. We also confirmed that the thermal noise of the n-coil, produced by its normal resistance, does not become higher than the intrinsic magnetic field noise of the SQUID.

Open-access reader

About this research paper

What this paper is about

We have investigated the performance of a normal conducting transfer coil (n-coil) for nondestructive evaluation with a SQUID. The transfer efficiency, which depends on frequency and wire impedance, has been calculated for several coil designs to determine the performance of the n-coil. We have fabricated a 30 mm diameter n-coil and examined its performance with a high- T C SQUID. If both the pick-up coil and the input coil have 50 turns, then at high frequencies the magnetic field produced by the input coil becomes 50% of the magnetic field at the pick-up coil, with a low cut-off frequency of 2 kHz. The experimental result agrees well with a numerical calculation, which suggests a magnitude of magnetic field detected by our SQUID equal to the magnitude of the quasi-uniform magnetic field produced by the input coil. We also confirmed that the thermal noise of the n-coil, produced by its normal resistance, does not become higher than the intrinsic magnetic field noise of the SQUID.

Why it matters

OpenAlex reports 17 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We have investigated the performance of a normal conducting transfer coil (n-coil) for nondestructive evaluation with a SQUID. The transfer efficiency, which depends on frequency and wire impedance, has been calculated for several coil designs to determine the performance of the n-coil. We have fabricated a 30 mm diameter n-coil and examined its performance with a high- T C SQUID. If both the pick-up coil and the input coil have 50 turns, then at high frequencies the magnetic field produced by the input coil becomes 50% of the magnetic field at the pick-up coil, with a low cut-off frequency of 2 kHz. The experimental result agrees well with a numerical calculation, which suggests a magnitude of magnetic field detected by our SQUID equal to the magnitude of the quasi-uniform magnetic field produced by the input coil. We also confirmed that the thermal noise of the n-coil, produced by its normal resistance, does not become higher than the intrinsic magnetic field noise of the SQUID.

Key concepts: Electromagnetic coil, Coil noise, Squid, Search coil, Nuclear magnetic resonance, Magnetic field, Materials science, Acoustics

Related papers

Back to paper searchBrowse research topicsOriginal source
Normal conducting transfer coil for SQUID NDE — Research Paper | ScholarLens