The release of β‐ thromboglobulin and platelet factor 4 during extracorporeal circulation for open heart surgery
Giuseppe Cella, ORNELLA VITTADELLO, Vincenzo Gallucci, Antonio Girolami
Abstract
Giuseppe Cella, ORNELLA VITTADELLO, Vincenzo Gallucci, Antonio Girolami
Abstract
Cardiopulmonary bypass is extremely damaging to platelets and it causes a quantitative and qualitative alteration in their functions. We evaluated the release of two platelet-specific proteins, beta-thromboglobulin (beta TG) and platelet factor 4 (PF4), in patients who underwent extracorporeal circulation for open heart surgery. A parallel release (basal value beta TG: 119.6 ng/ml, PF4 30 ng/ml) was present for both proteins in a time dependent fashion until the end of extracorporeal circulation. High average levels were observed in patients in whom the bypass was stopped after about 1 h (beta TG 1606 ng/ml, PF4 745 ng/ml) and similarly in those in whom the bypass was stopped after about 2 h (beta TG 1540 ng/ml, PF 4754 ng/ml). No correlation was found either between the level of PF4 and the additional heparin administered after the initial standard dose (r = 0.29, P greater than 0.10) and between the level of PF4 and the amount of heparin consumed during the bypass (r = 0.05, P greater than 0.5).
OpenAlex reports 45 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Cardiopulmonary bypass is extremely damaging to platelets and it causes a quantitative and qualitative alteration in their functions. We evaluated the release of two platelet-specific proteins, beta-thromboglobulin (beta TG) and platelet factor 4 (PF4), in patients who underwent extracorporeal circulation for open heart surgery. A parallel release (basal value beta TG: 119.6 ng/ml, PF4 30 ng/ml) was present for both proteins in a time dependent fashion until the end of extracorporeal circulation. High average levels were observed in patients in whom the bypass was stopped after about 1 h (beta TG 1606 ng/ml, PF4 745 ng/ml) and similarly in those in whom the bypass was stopped after about 2 h (beta TG 1540 ng/ml, PF 4754 ng/ml). No correlation was found either between the level of PF4 and the additional heparin administered after the initial standard dose (r = 0.29, P greater than 0.10) and between the level of PF4 and the amount of heparin consumed during the bypass (r = 0.05, P greater than 0.5).
Key concepts: Extracorporeal circulation, Cardiopulmonary bypass, Platelet factor 4, Platelet, Heparin, Extracorporeal, Medicine, Platelet activation