1939•Canadian Journal of Research/Canadian journal of researchRequires access

DEW-POINT HYGROMETER FOR USE AT LOW TEMPERATURES

Carl A. Winkler

Open publisher page 1 citations

Abstract

An apparatus is described in which provision for slow cooling of a metal mirror by circulating over it liquid from a vessel in a thermoregulated bath, and the use of multiple thermocouple elements contained in the mirror, enable the dew-point temperature to be gradually approached and accurately determined. Precise measurements of relative humidity at low temperatures, where the moisture content of the air is small, are therefore possible. A precision of ± 0.5% relative humidity was readily attained at temperatures down to − 15 °C.

About this research paper

What this paper is about

An apparatus is described in which provision for slow cooling of a metal mirror by circulating over it liquid from a vessel in a thermoregulated bath, and the use of multiple thermocouple elements contained in the mirror, enable the dew-point temperature to be gradually approached and accurately determined. Precise measurements of relative humidity at low temperatures, where the moisture content of the air is small, are therefore possible. A precision of ± 0.5% relative humidity was readily attained at temperatures down to − 15 °C.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

An apparatus is described in which provision for slow cooling of a metal mirror by circulating over it liquid from a vessel in a thermoregulated bath, and the use of multiple thermocouple elements contained in the mirror, enable the dew-point temperature to be gradually approached and accurately determined. Precise measurements of relative humidity at low temperatures, where the moisture content of the air is small, are therefore possible. A precision of ± 0.5% relative humidity was readily attained at temperatures down to − 15 °C.

Key concepts: Hygrometer, Dew point, Humidity, Relative humidity, Dew, Thermocouple, Environmental science, Critical relative humidity

Related papers

Back to paper searchBrowse research topicsOriginal source
DEW-POINT HYGROMETER FOR USE AT LOW TEMPERATURES — Research Paper | ScholarLens