Effect of the slow-component rise in oxygen uptake on ??VO2max
M. A. Sloniger, Kirk J. Cureton, Darío I. Carrasco, Barry M. Prior, David A. Rowe, Raymond W. Thompson
Abstract
M. A. Sloniger, Kirk J. Cureton, Darío I. Carrasco, Barry M. Prior, David A. Rowe, Raymond W. Thompson
Abstract
During constant-rate high-intensity (CRHI) exercise lasting longer than 3 min, VO2 has been reported to exceed VO2max measured with a traditional graded exercise test (GXT). This could be because VO2max was not achieved on the GXT or because the factors responsible for the slow-component rise in VO2 alter VO2max. The objective of this study was to test the hypothesis that the slow-component rise in VO2 measured during CRHI running leads to a total VO2 that exceeds VO2max measured during a running GXT. VO2max was determined in eight highly trained individuals using data collected from five grade-incremented, treadmill-running GXT. Each subject demonstrated a definitive plateau of VO2 as a function of exercise intensity. Three VO2max values based on different approaches for representing the VO2max plateau were obtained. Subjects also completed two exhaustive CRHI bouts of treadmill running lasting 7-13 min at speeds estimated from the ACSM equation to elicit an average of 99 +/- 5% VO2max. The mean (+/- SD) VO2peak determined during the CRHI runs (4.17 +/- 0.9 l.min-1) was not different form or less than the three VO2max values (4.19-4.32 +/- 0.09 l.min-1). We conclude that in highly trained individuals, the slow-component rise in VO2 during CRHI treadmill running does not lead to a total VO2 that exceeds the VO2max measured during a running graded exercise test.
OpenAlex reports 24 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
During constant-rate high-intensity (CRHI) exercise lasting longer than 3 min, VO2 has been reported to exceed VO2max measured with a traditional graded exercise test (GXT). This could be because VO2max was not achieved on the GXT or because the factors responsible for the slow-component rise in VO2 alter VO2max. The objective of this study was to test the hypothesis that the slow-component rise in VO2 measured during CRHI running leads to a total VO2 that exceeds VO2max measured during a running GXT. VO2max was determined in eight highly trained individuals using data collected from five grade-incremented, treadmill-running GXT. Each subject demonstrated a definitive plateau of VO2 as a function of exercise intensity. Three VO2max values based on different approaches for representing the VO2max plateau were obtained. Subjects also completed two exhaustive CRHI bouts of treadmill running lasting 7-13 min at speeds estimated from the ACSM equation to elicit an average of 99 +/- 5% VO2max. The mean (+/- SD) VO2peak determined during the CRHI runs (4.17 +/- 0.9 l.min-1) was not different form or less than the three VO2max values (4.19-4.32 +/- 0.09 l.min-1). We conclude that in highly trained individuals, the slow-component rise in VO2 during CRHI treadmill running does not lead to a total VO2 that exceeds the VO2max measured during a running graded exercise test.
Key concepts: VO2 max, Treadmill, Plateau (mathematics), Mathematics, Intensity (physics), Animal science, Heart rate, Physical therapy