Thermal crosslinking of collagen immobilized on poly(acrylic acid) grafted poly(ethylene terephthalate) films
Bhuvanesh Gupta, Jöns G. Hilborn, C. J. G. Plummer, Isabelle Bisson, Pascal Frey
Abstract
Bhuvanesh Gupta, Jöns G. Hilborn, C. J. G. Plummer, Isabelle Bisson, Pascal Frey
Abstract
Abstract Graft polymerization of acrylic acid onto plasma‐treated poly(ethylene terephthalate) (PET) films was used to prepare surfaces suitable for collagen immobilization by dip‐coating. Such surfaces could be used as matrices for smooth muscle cell cultures in tissue engineering. Contact angle measurements showed that plasma‐treated and grafted PET films undergo considerable surface reorganization during storage under ambient conditions. However, after collagen immobilization the contact angle remained relatively stable. The amount of collagen initially attached to the film surface increased with increasing poly(acrylic acid) graft density, but subsequent washing in water led to significant collagen loss. This loss could nevertheless be substantially reduced by thermal crosslinking of the collagen in the range 110–130 °C. Atomic force microscopy (AFM) observations suggested that the washed crosslinked collagen has a very similar structure to that of the un‐crosslinked collagen. © 2002 Wiley Periodicals, Inc. J Appl Polym Sci 85: 1874–1880, 2002
OpenAlex reports 16 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Abstract Graft polymerization of acrylic acid onto plasma‐treated poly(ethylene terephthalate) (PET) films was used to prepare surfaces suitable for collagen immobilization by dip‐coating. Such surfaces could be used as matrices for smooth muscle cell cultures in tissue engineering. Contact angle measurements showed that plasma‐treated and grafted PET films undergo considerable surface reorganization during storage under ambient conditions. However, after collagen immobilization the contact angle remained relatively stable. The amount of collagen initially attached to the film surface increased with increasing poly(acrylic acid) graft density, but subsequent washing in water led to significant collagen loss. This loss could nevertheless be substantially reduced by thermal crosslinking of the collagen in the range 110–130 °C. Atomic force microscopy (AFM) observations suggested that the washed crosslinked collagen has a very similar structure to that of the un‐crosslinked collagen. © 2002 Wiley Periodicals, Inc. J Appl Polym Sci 85: 1874–1880, 2002
Key concepts: Acrylic acid, Contact angle, Materials science, Polymer chemistry, Ethylene, Chemical engineering, Polymerization, Coating