2012Wind EngineeringRequires access

Improvement of the Low-Voltage Ride-through Capability of Doubly Fed Induction Generator Wind Turbines

Yu Ling, Zhenlan Dou, Qiang Gao, Xu Cai

Open publisher page 10 citations

Abstract

So far, active crowbars are a preferred technique for doubly fed induction generator (DFIG) wind turbines, which is used to protect the power converter against over-current and undesirably high dc link voltage during voltage dip. However, its main drawbacks are that (1) the DFIG absorbs reactive power from the grid during grid voltage dips, (2) the crowbar activation increases the acceleration of the rotor and so, deteriorates the dynamic stability of DFIG, and (3) the control is not flexible for long-time voltage sags. In the paper, three different initiating logic control methods of crowbar protection are compared, and how low-voltage ride-through (LVRT) characteristics of DFIG wind turbines with active crowbar are affected by different switching logic control modes of the crowbar are investigated. According to the comparison results, an improved crowbar switching control strategy is proposed to reduce its operation time and improve the LVRT capability of DFIG wind turbines. In addition, an emergency pitch blade angle control scheme to reduce the acceleration of the rotor and prevent the over-speeding of rotor is presented in detail, and as a result, the LVRT capability of DFIG wind turbines is enhanced even during long-time voltage sags. Finally, the presented control strategies are validated in simulation tool Matalab/Simulink for a 1.5MW generator.

About this research paper

What this paper is about

So far, active crowbars are a preferred technique for doubly fed induction generator (DFIG) wind turbines, which is used to protect the power converter against over-current and undesirably high dc link voltage during voltage dip. However, its main drawbacks are that (1) the DFIG absorbs reactive power from the grid during grid voltage dips, (2) the crowbar activation increases the acceleration of the rotor and so, deteriorates the dynamic stability of DFIG, and (3) the control is not flexible for long-time voltage sags. In the paper, three different initiating logic control methods of crowbar protection are compared, and how low-voltage ride-through (LVRT) characteristics of DFIG wind turbines with active crowbar are affected by different switching logic control modes of the crowbar are investigated. According to the comparison results, an improved crowbar switching control strategy is proposed to reduce its operation time and improve the LVRT capability of DFIG wind turbines. In addition, an emergency pitch blade angle control scheme to reduce the acceleration of the rotor and prevent the over-speeding of rotor is presented in detail, and as a result, the LVRT capability of DFIG wind turbines is enhanced even during long-time voltage sags. Finally, the presented control strategies are validated in simulation tool Matalab/Simulink for a 1.5MW generator.

Why it matters

OpenAlex reports 10 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

So far, active crowbars are a preferred technique for doubly fed induction generator (DFIG) wind turbines, which is used to protect the power converter against over-current and undesirably high dc link voltage during voltage dip. However, its main drawbacks are that (1) the DFIG absorbs reactive power from the grid during grid voltage dips, (2) the crowbar activation increases the acceleration of the rotor and so, deteriorates the dynamic stability of DFIG, and (3) the control is not flexible for long-time voltage sags. In the paper, three different initiating logic control methods of crowbar protection are compared, and how low-voltage ride-through (LVRT) characteristics of DFIG wind turbines with active crowbar are affected by different switching logic control modes of the crowbar are investigated. According to the comparison results, an improved crowbar switching control strategy is proposed to reduce its operation time and improve the LVRT capability of DFIG wind turbines. In addition, an emergency pitch blade angle control scheme to reduce the acceleration of the rotor and prevent the over-speeding of rotor is presented in detail, and as a result, the LVRT capability of DFIG wind turbines is enhanced even during long-time voltage sags. Finally, the presented control strategies are validated in simulation tool Matalab/Simulink for a 1.5MW generator.

Key concepts: Crowbar, Low voltage ride through, Wind power, Rotor (electric), Induction generator, Control theory (sociology), Voltage, AC power

Related papers

Back to paper searchBrowse research topicsOriginal source
Improvement of the Low-Voltage Ride-through Capability of Doubly Fed Induction Generator Wind Turbines — Research Paper | ScholarLens