2014Unpublished venueRequires access

Gas mixture control system for oxygen therapy in pre-term infants

Phattaradanai Kiratiwudhikul, Pornchai Chanyagorn

Open publisher page 3 citations

Abstract

Pre-term infants - less than 37 weeks gestational age - usually had immature lungs' development, which resulted of poor oxygen saturation in red blood cells. A blood oxygen saturation level was measured in percent of Peripheral capillary oxygen saturation (SpO2). Medical doctors needed to order an oxygen therapy to maintain SpO2 of the infants between 90-95% while SpO2 of normal infants is 99-100%. Oxygen therapy was a procedure to stimulate lung functions and to maintain life. A registered nurse (RN) was responsible for adjusting levels of a fractional of inspired oxygen (FiO2) from 21% to 100% which was a proportion of oxygen gas provided to the infants periodically. In real situation, the adjustment could only be made as often as every 20-30 minutes, which might not be adequate. This caused ineffectiveness of an oxygen therapy and result in a longer hospital stay. A critical error of this adjustment could also cause blindness due to oxygen toxicity or dead due to hypoxia. This research was to develop a reliable embedded system that allowed automatically control of FiO2 according to an order of SpO2 by medical doctors. As a result, risks of oxygen toxicity and hypoxia could be minimized. The system also allowed medical doctors to use recorded data for future care planning in oxygen therapy.

About this research paper

What this paper is about

Pre-term infants - less than 37 weeks gestational age - usually had immature lungs' development, which resulted of poor oxygen saturation in red blood cells. A blood oxygen saturation level was measured in percent of Peripheral capillary oxygen saturation (SpO2). Medical doctors needed to order an oxygen therapy to maintain SpO2 of the infants between 90-95% while SpO2 of normal infants is 99-100%. Oxygen therapy was a procedure to stimulate lung functions and to maintain life. A registered nurse (RN) was responsible for adjusting levels of a fractional of inspired oxygen (FiO2) from 21% to 100% which was a proportion of oxygen gas provided to the infants periodically. In real situation, the adjustment could only be made as often as every 20-30 minutes, which might not be adequate. This caused ineffectiveness of an oxygen therapy and result in a longer hospital stay. A critical error of this adjustment could also cause blindness due to oxygen toxicity or dead due to hypoxia. This research was to develop a reliable embedded system that allowed automatically control of FiO2 according to an order of SpO2 by medical doctors. As a result, risks of oxygen toxicity and hypoxia could be minimized. The system also allowed medical doctors to use recorded data for future care planning in oxygen therapy.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Pre-term infants - less than 37 weeks gestational age - usually had immature lungs' development, which resulted of poor oxygen saturation in red blood cells. A blood oxygen saturation level was measured in percent of Peripheral capillary oxygen saturation (SpO2). Medical doctors needed to order an oxygen therapy to maintain SpO2 of the infants between 90-95% while SpO2 of normal infants is 99-100%. Oxygen therapy was a procedure to stimulate lung functions and to maintain life. A registered nurse (RN) was responsible for adjusting levels of a fractional of inspired oxygen (FiO2) from 21% to 100% which was a proportion of oxygen gas provided to the infants periodically. In real situation, the adjustment could only be made as often as every 20-30 minutes, which might not be adequate. This caused ineffectiveness of an oxygen therapy and result in a longer hospital stay. A critical error of this adjustment could also cause blindness due to oxygen toxicity or dead due to hypoxia. This research was to develop a reliable embedded system that allowed automatically control of FiO2 according to an order of SpO2 by medical doctors. As a result, risks of oxygen toxicity and hypoxia could be minimized. The system also allowed medical doctors to use recorded data for future care planning in oxygen therapy.

Key concepts: Oxygen toxicity, Oxygen therapy, Oxygen, Hypoxia (environmental), Oxygen saturation, Medicine, Hyperoxia, Retinopathy of prematurity

Related papers

Back to paper searchBrowse research topicsOriginal source
Gas mixture control system for oxygen therapy in pre-term infants — Research Paper | ScholarLens