2010•Geotechnical Testing JournalRequires access

Field Behavior of a Geogrid Reinforced Soil Retaining Wall with a Wrap-Around Facing

Guangqing Yang, Junxia Ding, Qiao-Yong Zhou, Baojian Zhang

Open publisher page 31 citations

Abstract

Abstract The earth pressure and deformation characteristics of a geogrid reinforced soil retaining wall were monitored during and for a period of 1.5 years after construction. Both vertical and lateral soil stresses were recorded with vibrating-wire earth pressure cells, and the reinforcement deformations were measured using flexible displacement sensors. The maximum vertical foundation pressure along the wall’s reinforcements occurred at the center of the reinforcement, gradually decreasing towards the front and back ends. The measured lateral earth pressure within the reinforced soil wall is non-linear along the wall height, and the value is less than the theoretical active lateral earth pressure. The distribution of tensile strain along the reinforcements within the lower portion of the wall has two peak values. The potential failure surface of the wall closely follows the theoretical Coulomb failure surface of an unreinforced backfill.

About this research paper

What this paper is about

Abstract The earth pressure and deformation characteristics of a geogrid reinforced soil retaining wall were monitored during and for a period of 1.5 years after construction. Both vertical and lateral soil stresses were recorded with vibrating-wire earth pressure cells, and the reinforcement deformations were measured using flexible displacement sensors. The maximum vertical foundation pressure along the wall’s reinforcements occurred at the center of the reinforcement, gradually decreasing towards the front and back ends. The measured lateral earth pressure within the reinforced soil wall is non-linear along the wall height, and the value is less than the theoretical active lateral earth pressure. The distribution of tensile strain along the reinforcements within the lower portion of the wall has two peak values. The potential failure surface of the wall closely follows the theoretical Coulomb failure surface of an unreinforced backfill.

Why it matters

OpenAlex reports 31 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract The earth pressure and deformation characteristics of a geogrid reinforced soil retaining wall were monitored during and for a period of 1.5 years after construction. Both vertical and lateral soil stresses were recorded with vibrating-wire earth pressure cells, and the reinforcement deformations were measured using flexible displacement sensors. The maximum vertical foundation pressure along the wall’s reinforcements occurred at the center of the reinforcement, gradually decreasing towards the front and back ends. The measured lateral earth pressure within the reinforced soil wall is non-linear along the wall height, and the value is less than the theoretical active lateral earth pressure. The distribution of tensile strain along the reinforcements within the lower portion of the wall has two peak values. The potential failure surface of the wall closely follows the theoretical Coulomb failure surface of an unreinforced backfill.

Key concepts: Geogrid, Lateral earth pressure, Retaining wall, Geotechnical engineering, Deformation (meteorology), Reinforcement, Displacement (psychology), Materials science

Related papers

Back to paper searchBrowse research topicsOriginal source
Field Behavior of a Geogrid Reinforced Soil Retaining Wall with a Wrap-Around Facing — Research Paper | ScholarLens