1987Medical PhysicsRequires access

A technique for computing dose volume histograms for structure combinations

Radhe Mohan, Linda J. Brewster, Glenn D. Barest

Open publisher page 10 citations

Abstract

Graphical displays of three-dimensional dose distribution data are often too complex to be easily assimilated and interpreted for the evaluation of radiation treatment plans. Histograms showing dose versus volume are convenient and useful tools for summarizing dose distribution information throughout the entire volume of a given anatomic structure. They can quickly highlight characteristics such as dose uniformity and hot and cold spots, and can be used to produce statistics including tumor control and normal tissue complication probabilities. To obtain a dose volume histogram for a given structure, it may be necessary to examine its spatial relationships with neighboring structures. They may overlap, be completely disjoint, or one may be contained within another. To resolve potential ambiguities, a procedure has been developed that assigns hierarchies to anatomical structures for the purpose of histogram calculation. The hierarchy assigned to each structure is used to determine the structure within which a given dose matrix point is considered to lie. In this manner, regions of structure intersection are assigned to one object or another, and dose volume histograms can be calculated for each structure separately. From this framework, addition and subtraction of histograms can also be performed. Details of the algorithm are presented along with an example using patient data.

About this research paper

What this paper is about

Graphical displays of three-dimensional dose distribution data are often too complex to be easily assimilated and interpreted for the evaluation of radiation treatment plans. Histograms showing dose versus volume are convenient and useful tools for summarizing dose distribution information throughout the entire volume of a given anatomic structure. They can quickly highlight characteristics such as dose uniformity and hot and cold spots, and can be used to produce statistics including tumor control and normal tissue complication probabilities. To obtain a dose volume histogram for a given structure, it may be necessary to examine its spatial relationships with neighboring structures. They may overlap, be completely disjoint, or one may be contained within another. To resolve potential ambiguities, a procedure has been developed that assigns hierarchies to anatomical structures for the purpose of histogram calculation. The hierarchy assigned to each structure is used to determine the structure within which a given dose matrix point is considered to lie. In this manner, regions of structure intersection are assigned to one object or another, and dose volume histograms can be calculated for each structure separately. From this framework, addition and subtraction of histograms can also be performed. Details of the algorithm are presented along with an example using patient data.

Why it matters

OpenAlex reports 10 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Graphical displays of three-dimensional dose distribution data are often too complex to be easily assimilated and interpreted for the evaluation of radiation treatment plans. Histograms showing dose versus volume are convenient and useful tools for summarizing dose distribution information throughout the entire volume of a given anatomic structure. They can quickly highlight characteristics such as dose uniformity and hot and cold spots, and can be used to produce statistics including tumor control and normal tissue complication probabilities. To obtain a dose volume histogram for a given structure, it may be necessary to examine its spatial relationships with neighboring structures. They may overlap, be completely disjoint, or one may be contained within another. To resolve potential ambiguities, a procedure has been developed that assigns hierarchies to anatomical structures for the purpose of histogram calculation. The hierarchy assigned to each structure is used to determine the structure within which a given dose matrix point is considered to lie. In this manner, regions of structure intersection are assigned to one object or another, and dose volume histograms can be calculated for each structure separately. From this framework, addition and subtraction of histograms can also be performed. Details of the algorithm are presented along with an example using patient data.

Key concepts: Histogram, Dose-volume histogram, Volume (thermodynamics), Subtraction, Disjoint sets, Intersection (aeronautics), Algorithm, Computer science

Related papers

Back to paper searchBrowse research topicsOriginal source
A technique for computing dose volume histograms for structure combinations — Research Paper | ScholarLens