Separation and quantification of flavonoid compounds inRhododendron anthopogonoidesMaxim by high-performance liquid chromatography
Liang Zhao, Jiahui Ge, C. Qiao, H. Zhang, Shengxiang Jiang
Abstract
Open-access reader
Liang Zhao, Jiahui Ge, C. Qiao, H. Zhang, Shengxiang Jiang
Abstract
Open-access reader
A high-performance liquid chromatographic (HPLC) method has been developed for separation and quantitative analysis of flavonoid aglycones in Rhododendron anthropogonosides Maxim. Flavonoids in their bound forms were hydrolyzed with acid before HPLC analysis. Analytical samples were pretreated by solid-phase extraction on C18 reversed-phase cartridges. Optimum separation on a 4.6 mm × 250 mm i.d. C18 column was achieved by use of a 52:48 (v/v) mixture of methanol and an aqueous solution of 10 mm citric acid and 1 mm sodium dodecyl sulfate as mobile phase. The flow rate was 1.0 mL min–1 and the detection wavelength 360 nm. Five flavonoids, myricetin, quercetin, luteolin, kaempferol, and isorhamnetin, were separated with high resolution without use of gradient elution. The method was successfully used for efficient quality-control analysis by quantifying flavonoids in R. anthopogonosides. Repeatability tests showed that intra-day and inter-day RSD was <10%. LOD of the five flavonoids were <0.85 μg mL–1. Recovery ranged from 90.2 to 112.5%, with RSD <11.1%.
OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A high-performance liquid chromatographic (HPLC) method has been developed for separation and quantitative analysis of flavonoid aglycones in Rhododendron anthropogonosides Maxim. Flavonoids in their bound forms were hydrolyzed with acid before HPLC analysis. Analytical samples were pretreated by solid-phase extraction on C18 reversed-phase cartridges. Optimum separation on a 4.6 mm × 250 mm i.d. C18 column was achieved by use of a 52:48 (v/v) mixture of methanol and an aqueous solution of 10 mm citric acid and 1 mm sodium dodecyl sulfate as mobile phase. The flow rate was 1.0 mL min–1 and the detection wavelength 360 nm. Five flavonoids, myricetin, quercetin, luteolin, kaempferol, and isorhamnetin, were separated with high resolution without use of gradient elution. The method was successfully used for efficient quality-control analysis by quantifying flavonoids in R. anthopogonosides. Repeatability tests showed that intra-day and inter-day RSD was <10%. LOD of the five flavonoids were <0.85 μg mL–1. Recovery ranged from 90.2 to 112.5%, with RSD <11.1%.
Key concepts: Chemistry, Chromatography, High-performance liquid chromatography, Kaempferol, Flavonoid, Repeatability, Myricetin, Quercetin