2002AnaesthesiaRequires access

Comparison of times to achieve tracheal intubation with three techniques using the laryngeal or intubating laryngeal mask airway*

Jaideep J. Pandit, K. MacLachlan, R. M. Dravid, M. Popat

Open publisher page 76 citations

Abstract

We compared the times to intubate the trachea using three techniques in 60 healthy patients with normal airways: (i) fibreoptic intubation with a 6.0-mm reinforced tracheal tube through a standard laryngeal mask airway (laryngeal mask-fibreoptic group); (ii) fibreoptic intubation with a dedicated 7.0-mm silicone tracheal tube through the intubating laryngeal mask airway (intubating laryngeal mask-fibreoptic group); (iii) blind intubation with the dedicated 7.0-mm silicone tracheal tube through the intubating laryngeal mask airway (intubating laryngeal mask-blind group). Mean (SD) total intubation times were significantly shorter in the intubating laryngeal mask-blind group (49 (20) s) than in either of the other two groups (intubating laryngeal mask-fibreoptic 74 (21) s; laryngeal mask-fibreoptic group 75 (36) s; p < 0.001). However, intubation at the first attempt was less successful with the intubating laryngeal mask-blind technique (15/20 (75%)) than in the other two groups (intubating laryngeal mask-fibreoptic 19/20 (95%) and laryngeal mask-fibreoptic 16/20 (80%)) although these differences were not statistically significant. We conclude that in this patient group, all three techniques yield acceptable results. If there is a choice of techniques available, the intubating laryngeal mask-blind technique would result in the shortest intubation time.

About this research paper

What this paper is about

We compared the times to intubate the trachea using three techniques in 60 healthy patients with normal airways: (i) fibreoptic intubation with a 6.0-mm reinforced tracheal tube through a standard laryngeal mask airway (laryngeal mask-fibreoptic group); (ii) fibreoptic intubation with a dedicated 7.0-mm silicone tracheal tube through the intubating laryngeal mask airway (intubating laryngeal mask-fibreoptic group); (iii) blind intubation with the dedicated 7.0-mm silicone tracheal tube through the intubating laryngeal mask airway (intubating laryngeal mask-blind group). Mean (SD) total intubation times were significantly shorter in the intubating laryngeal mask-blind group (49 (20) s) than in either of the other two groups (intubating laryngeal mask-fibreoptic 74 (21) s; laryngeal mask-fibreoptic group 75 (36) s; p < 0.001). However, intubation at the first attempt was less successful with the intubating laryngeal mask-blind technique (15/20 (75%)) than in the other two groups (intubating laryngeal mask-fibreoptic 19/20 (95%) and laryngeal mask-fibreoptic 16/20 (80%)) although these differences were not statistically significant. We conclude that in this patient group, all three techniques yield acceptable results. If there is a choice of techniques available, the intubating laryngeal mask-blind technique would result in the shortest intubation time.

Why it matters

OpenAlex reports 76 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We compared the times to intubate the trachea using three techniques in 60 healthy patients with normal airways: (i) fibreoptic intubation with a 6.0-mm reinforced tracheal tube through a standard laryngeal mask airway (laryngeal mask-fibreoptic group); (ii) fibreoptic intubation with a dedicated 7.0-mm silicone tracheal tube through the intubating laryngeal mask airway (intubating laryngeal mask-fibreoptic group); (iii) blind intubation with the dedicated 7.0-mm silicone tracheal tube through the intubating laryngeal mask airway (intubating laryngeal mask-blind group). Mean (SD) total intubation times were significantly shorter in the intubating laryngeal mask-blind group (49 (20) s) than in either of the other two groups (intubating laryngeal mask-fibreoptic 74 (21) s; laryngeal mask-fibreoptic group 75 (36) s; p < 0.001). However, intubation at the first attempt was less successful with the intubating laryngeal mask-blind technique (15/20 (75%)) than in the other two groups (intubating laryngeal mask-fibreoptic 19/20 (95%) and laryngeal mask-fibreoptic 16/20 (80%)) although these differences were not statistically significant. We conclude that in this patient group, all three techniques yield acceptable results. If there is a choice of techniques available, the intubating laryngeal mask-blind technique would result in the shortest intubation time.

Key concepts: Medicine, Mascara, Intubation, Laryngeal Masks, Larynx, Laryngeal mask airway, Tracheal tube, Anesthesia

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparison of times to achieve tracheal intubation with three techniques using the laryngeal or intubating laryngeal mask airway* — Research Paper | ScholarLens