1970Bulletin of the Chemical Society of JapanRequires access

The Precise Coulometric Titration of the Acidic Primary Standard using Amperometric End-point Detection

Takayoshi Yoshimori, Ikuko Matsubara

Open publisher page 9 citations

Abstract

Abstract The sensitive amperometric end-point procedure (Anal. Chem., 23, 1662 (1951)) with an antimony electrode is used in the titrations of acids. The cyclic voltammetric curves of the electrode indicate the possibility of the use of the above method for the titration of acids. The purities of potassium biphthalates (primary standard substances) are determined directly by precise coulometric titration with this end-point location. The standard deviations of the results (99.999%) are 0.007 or 0.008%. The purity of the benzoic acid prepared as the standard material for the calorimeter is also determined by this method. The standard deviation of these results (99.993%) is 0.009%.

About this research paper

What this paper is about

Abstract The sensitive amperometric end-point procedure (Anal. Chem., 23, 1662 (1951)) with an antimony electrode is used in the titrations of acids. The cyclic voltammetric curves of the electrode indicate the possibility of the use of the above method for the titration of acids. The purities of potassium biphthalates (primary standard substances) are determined directly by precise coulometric titration with this end-point location. The standard deviations of the results (99.999%) are 0.007 or 0.008%. The purity of the benzoic acid prepared as the standard material for the calorimeter is also determined by this method. The standard deviation of these results (99.993%) is 0.009%.

Why it matters

OpenAlex reports 9 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract The sensitive amperometric end-point procedure (Anal. Chem., 23, 1662 (1951)) with an antimony electrode is used in the titrations of acids. The cyclic voltammetric curves of the electrode indicate the possibility of the use of the above method for the titration of acids. The purities of potassium biphthalates (primary standard substances) are determined directly by precise coulometric titration with this end-point location. The standard deviations of the results (99.999%) are 0.007 or 0.008%. The purity of the benzoic acid prepared as the standard material for the calorimeter is also determined by this method. The standard deviation of these results (99.993%) is 0.009%.

Key concepts: Coulometry, Chemistry, Amperometry, Titration, End point, Amperometric titration, Chromatography, Primary (astronomy)

Related papers

Back to paper searchBrowse research topicsOriginal source
The Precise Coulometric Titration of the Acidic Primary Standard using Amperometric End-point Detection — Research Paper | ScholarLens