A segmented concentric Faraday cup for measurement of time-dependent relativistic electron beam profiles
Thomas A. Peyser, John A. Antoniades, Matthew C. Myers, Mártin Lampe, R. E. Pechacek, Donald P. Murphy, Robert A. Meger
Abstract
Thomas A. Peyser, John A. Antoniades, Matthew C. Myers, Mártin Lampe, R. E. Pechacek, Donald P. Murphy, Robert A. Meger
Abstract
A multi-element segmented concentric Faraday collector has been developed for measuring the time evolution of the beam half-current radius (a1/2) of an intense relativistic electron beam. Each collector segment measures the total current within its radius. The data analysis procedure fits the data from all five segments at a given time to a prescribed beam profile and calculates a1/2 from the parameters of the fitted curves. The effect of beam centroid offsets on the data analysis was investigated numerically. Beam centroid offsets as large as half the beam radius produce only a 10% error in the experimental measurement of a1/2. The use of a thin graphite overlayer followed by range-thick stainless steel reduces scattering from one collector element to the next. The instrument has been used extensively on the SuperIBEX relativistic electron beam accelerator for measurement of the half-current radius as a function of time. Radius variations in excess of 4:1 have been measured over the duration of the beam pulse for beams with 5-MeV energy, 20-kA peak current and 1-cm final half-current radii.
OpenAlex reports 11 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A multi-element segmented concentric Faraday collector has been developed for measuring the time evolution of the beam half-current radius (a1/2) of an intense relativistic electron beam. Each collector segment measures the total current within its radius. The data analysis procedure fits the data from all five segments at a given time to a prescribed beam profile and calculates a1/2 from the parameters of the fitted curves. The effect of beam centroid offsets on the data analysis was investigated numerically. Beam centroid offsets as large as half the beam radius produce only a 10% error in the experimental measurement of a1/2. The use of a thin graphite overlayer followed by range-thick stainless steel reduces scattering from one collector element to the next. The instrument has been used extensively on the SuperIBEX relativistic electron beam accelerator for measurement of the half-current radius as a function of time. Radius variations in excess of 4:1 have been measured over the duration of the beam pulse for beams with 5-MeV energy, 20-kA peak current and 1-cm final half-current radii.
Key concepts: Faraday cup, Beam (structure), RADIUS, Physics, Beam diameter, Optics, Relativistic electron beam, Cathode ray