2002Journal of Vascular ResearchRequires access

External Collar Inhibits Balloon-Induced Intimal Hyperplasia in Rabbits

Per Fogelstrand, B Risberg, Erney Mattsson

Open publisher page 7 citations

Abstract

Intimal hyperplasia is a common complication following vascular interventions. To understand the underlying pathophysiology, the focus has mainly been on the intima and media. The adventitia has been less investigated, although adventitial hyperplasia is seen together with intimal hyperplasia. If the adventitial response is an important part of the process, the adventitia might be a target to inhibit intimal hyperplasia. In the present study we investigated whether an external collar attenuating the adventitial thickness could inhibit a balloon-induced intimal hyperplasia. The common carotid artery was injured in rabbits (n = 6) with a 3-french balloon catheter. The mid portion of the injured artery was encircled with a silicone collar (diameter = 2.0 mm). After 14 days the balloon-induced neointima was reduced by 54 +/- 6.3% underneath the collar. The adventitial and medial thickenings were also attenuated (36 +/- 8.7 and 44 +/- 4.3%, respectively). This study demonstrates that intimal hyperplasia following balloon injury can be inhibited with an external collar. This supports the idea of the adventitia as a potential target to inhibit intimal hyperplasia.

About this research paper

What this paper is about

Intimal hyperplasia is a common complication following vascular interventions. To understand the underlying pathophysiology, the focus has mainly been on the intima and media. The adventitia has been less investigated, although adventitial hyperplasia is seen together with intimal hyperplasia. If the adventitial response is an important part of the process, the adventitia might be a target to inhibit intimal hyperplasia. In the present study we investigated whether an external collar attenuating the adventitial thickness could inhibit a balloon-induced intimal hyperplasia. The common carotid artery was injured in rabbits (n = 6) with a 3-french balloon catheter. The mid portion of the injured artery was encircled with a silicone collar (diameter = 2.0 mm). After 14 days the balloon-induced neointima was reduced by 54 +/- 6.3% underneath the collar. The adventitial and medial thickenings were also attenuated (36 +/- 8.7 and 44 +/- 4.3%, respectively). This study demonstrates that intimal hyperplasia following balloon injury can be inhibited with an external collar. This supports the idea of the adventitia as a potential target to inhibit intimal hyperplasia.

Why it matters

OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Intimal hyperplasia is a common complication following vascular interventions. To understand the underlying pathophysiology, the focus has mainly been on the intima and media. The adventitia has been less investigated, although adventitial hyperplasia is seen together with intimal hyperplasia. If the adventitial response is an important part of the process, the adventitia might be a target to inhibit intimal hyperplasia. In the present study we investigated whether an external collar attenuating the adventitial thickness could inhibit a balloon-induced intimal hyperplasia. The common carotid artery was injured in rabbits (n = 6) with a 3-french balloon catheter. The mid portion of the injured artery was encircled with a silicone collar (diameter = 2.0 mm). After 14 days the balloon-induced neointima was reduced by 54 +/- 6.3% underneath the collar. The adventitial and medial thickenings were also attenuated (36 +/- 8.7 and 44 +/- 4.3%, respectively). This study demonstrates that intimal hyperplasia following balloon injury can be inhibited with an external collar. This supports the idea of the adventitia as a potential target to inhibit intimal hyperplasia.

Key concepts: Adventitia, Intimal hyperplasia, Neointima, Medicine, Hyperplasia, Balloon, Balloon catheter, Angioplasty