External Collar Inhibits Balloon-Induced Intimal Hyperplasia in Rabbits
Per Fogelstrand, B Risberg, Erney Mattsson
Abstract
Per Fogelstrand, B Risberg, Erney Mattsson
Abstract
Intimal hyperplasia is a common complication following vascular interventions. To understand the underlying pathophysiology, the focus has mainly been on the intima and media. The adventitia has been less investigated, although adventitial hyperplasia is seen together with intimal hyperplasia. If the adventitial response is an important part of the process, the adventitia might be a target to inhibit intimal hyperplasia. In the present study we investigated whether an external collar attenuating the adventitial thickness could inhibit a balloon-induced intimal hyperplasia. The common carotid artery was injured in rabbits (n = 6) with a 3-french balloon catheter. The mid portion of the injured artery was encircled with a silicone collar (diameter = 2.0 mm). After 14 days the balloon-induced neointima was reduced by 54 +/- 6.3% underneath the collar. The adventitial and medial thickenings were also attenuated (36 +/- 8.7 and 44 +/- 4.3%, respectively). This study demonstrates that intimal hyperplasia following balloon injury can be inhibited with an external collar. This supports the idea of the adventitia as a potential target to inhibit intimal hyperplasia.
OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Intimal hyperplasia is a common complication following vascular interventions. To understand the underlying pathophysiology, the focus has mainly been on the intima and media. The adventitia has been less investigated, although adventitial hyperplasia is seen together with intimal hyperplasia. If the adventitial response is an important part of the process, the adventitia might be a target to inhibit intimal hyperplasia. In the present study we investigated whether an external collar attenuating the adventitial thickness could inhibit a balloon-induced intimal hyperplasia. The common carotid artery was injured in rabbits (n = 6) with a 3-french balloon catheter. The mid portion of the injured artery was encircled with a silicone collar (diameter = 2.0 mm). After 14 days the balloon-induced neointima was reduced by 54 +/- 6.3% underneath the collar. The adventitial and medial thickenings were also attenuated (36 +/- 8.7 and 44 +/- 4.3%, respectively). This study demonstrates that intimal hyperplasia following balloon injury can be inhibited with an external collar. This supports the idea of the adventitia as a potential target to inhibit intimal hyperplasia.
Key concepts: Adventitia, Intimal hyperplasia, Neointima, Medicine, Hyperplasia, Balloon, Balloon catheter, Angioplasty