A single-voxel proton magnetic resonance spectroscopy ((1)H-MRS) method is described that enables the in vivo measurement of endogenous brain glycine (Gly) levels in human subjects. At 4.0 T, TE-averaging (1)H-MRS dramatically attenuates the overlapping myo-inositol (mI) resonances at 3.52 ppm, permitting a more reliable measure of the Gly singlet peak. This methodology initially is described and tested in phantoms. The phantom data infers that the 3.55-ppm peak predominantly is Gly with a smaller contribution from mI. The composite resonance thus is differentiated from pure Gly and mI and is labeled Gly*. The mI contribution was calculated as <2% of the total Gly* signal for a 1:1 mI/Gly mixture. The technique subsequently was used to acquire TE-averaged (1)H-MRS data from the occipital cortex of healthy control subjects. The resultant spectra closely resembled experimental phantom data. LC-model analysis provided a means for quantifying TE-averaged (1)H-MRS spectra and a mean test-retest variability measure of 15% was established for brain Gly* levels in studies of six healthy subjects.

Open-access reader

About this research paper

What this paper is about

A single-voxel proton magnetic resonance spectroscopy ((1)H-MRS) method is described that enables the in vivo measurement of endogenous brain glycine (Gly) levels in human subjects. At 4.0 T, TE-averaging (1)H-MRS dramatically attenuates the overlapping myo-inositol (mI) resonances at 3.52 ppm, permitting a more reliable measure of the Gly singlet peak. This methodology initially is described and tested in phantoms. The phantom data infers that the 3.55-ppm peak predominantly is Gly with a smaller contribution from mI. The composite resonance thus is differentiated from pure Gly and mI and is labeled Gly*. The mI contribution was calculated as <2% of the total Gly* signal for a 1:1 mI/Gly mixture. The technique subsequently was used to acquire TE-averaged (1)H-MRS data from the occipital cortex of healthy control subjects. The resultant spectra closely resembled experimental phantom data. LC-model analysis provided a means for quantifying TE-averaged (1)H-MRS spectra and a mean test-retest variability measure of 15% was established for brain Gly* levels in studies of six healthy subjects.

Why it matters

OpenAlex reports 41 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A single-voxel proton magnetic resonance spectroscopy ((1)H-MRS) method is described that enables the in vivo measurement of endogenous brain glycine (Gly) levels in human subjects. At 4.0 T, TE-averaging (1)H-MRS dramatically attenuates the overlapping myo-inositol (mI) resonances at 3.52 ppm, permitting a more reliable measure of the Gly singlet peak. This methodology initially is described and tested in phantoms. The phantom data infers that the 3.55-ppm peak predominantly is Gly with a smaller contribution from mI. The composite resonance thus is differentiated from pure Gly and mI and is labeled Gly*. The mI contribution was calculated as <2% of the total Gly* signal for a 1:1 mI/Gly mixture. The technique subsequently was used to acquire TE-averaged (1)H-MRS data from the occipital cortex of healthy control subjects. The resultant spectra closely resembled experimental phantom data. LC-model analysis provided a means for quantifying TE-averaged (1)H-MRS spectra and a mean test-retest variability measure of 15% was established for brain Gly* levels in studies of six healthy subjects.