Abstract

The voltage (or, equivalently, energy) at which defibrillation occurs for a specific episode of fibrillation can be represented by specifying or estimating the probability of successful defibrillation for each voltage or energy. This relation of voltage to probability is the probability function. For a series of attempts, the probability function predicts the frequency with which defibrillation will occur at a given voltage. By defining the defibrillation threshold (DFT) as the voltage at which the probability function takes on a specific value, say 50%, a method of defibrillation threshold determination can be evaluated by how accurately and precisely it estimates the "true" defibrillation threshold. By utilizing estimated probability functions from animals and humans, the relative performance of different methods of defibrillation threshold determination can be evaluated. Three methods were evaluated using published animal data and human clinical data: (1) stepping down to the first voltage that fails; (2) stepping up to the first voltage that succeeds; and (3) doing both 1 and 2 and averaging. In all cases, Method 3 has lower total error. Definitions of defibrillation threshold other than the 50% level can also be evaluated in this fashion.

About this research paper

What this paper is about

The voltage (or, equivalently, energy) at which defibrillation occurs for a specific episode of fibrillation can be represented by specifying or estimating the probability of successful defibrillation for each voltage or energy. This relation of voltage to probability is the probability function. For a series of attempts, the probability function predicts the frequency with which defibrillation will occur at a given voltage. By defining the defibrillation threshold (DFT) as the voltage at which the probability function takes on a specific value, say 50%, a method of defibrillation threshold determination can be evaluated by how accurately and precisely it estimates the "true" defibrillation threshold. By utilizing estimated probability functions from animals and humans, the relative performance of different methods of defibrillation threshold determination can be evaluated. Three methods were evaluated using published animal data and human clinical data: (1) stepping down to the first voltage that fails; (2) stepping up to the first voltage that succeeds; and (3) doing both 1 and 2 and averaging. In all cases, Method 3 has lower total error. Definitions of defibrillation threshold other than the 50% level can also be evaluated in this fashion.

Why it matters

OpenAlex reports 28 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The voltage (or, equivalently, energy) at which defibrillation occurs for a specific episode of fibrillation can be represented by specifying or estimating the probability of successful defibrillation for each voltage or energy. This relation of voltage to probability is the probability function. For a series of attempts, the probability function predicts the frequency with which defibrillation will occur at a given voltage. By defining the defibrillation threshold (DFT) as the voltage at which the probability function takes on a specific value, say 50%, a method of defibrillation threshold determination can be evaluated by how accurately and precisely it estimates the "true" defibrillation threshold. By utilizing estimated probability functions from animals and humans, the relative performance of different methods of defibrillation threshold determination can be evaluated. Three methods were evaluated using published animal data and human clinical data: (1) stepping down to the first voltage that fails; (2) stepping up to the first voltage that succeeds; and (3) doing both 1 and 2 and averaging. In all cases, Method 3 has lower total error. Definitions of defibrillation threshold other than the 50% level can also be evaluated in this fashion.

Key concepts: Defibrillation, Defibrillation threshold, Medicine, Voltage, Ventricular fibrillation, Fibrillation, Cardiology, Internal medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
A Model to Evaluate Alternative Methods of Defibrillation Threshold Determination — Research Paper | ScholarLens