2002Review of Scientific InstrumentsRequires access

The application of the photopyroelectric method for measuring the thermal parameters of pyroelectric materials

A. Hadj Sahraoui, S. Longuemart, D. Dǎdârlat, S. Delenclos, C. Kolinsky, J. M. Buisine

Open publisher page 32 citations

Abstract

The photopyroelectric calorimetry, in the standard (back) configuration, is applied in order to measure the thermal parameters of some pyroelectric materials. It is demonstrated that the method is able to simultaneously measure the thermal diffusivity and effusivity of a pyroelectric material. The information is obtained via a frequency scan of the amplitude or the phase of the pyroelectric signal; the measurements need no calibration. A combined amplitude-phase procedure, at a single frequency, leads to the same results. In the mean time, if the thermal parameters of the pyroelectric sensor are known, one can get the thermal effusivity of a sample acting in the experimental cell as a substrate. Investigations and theoretical simulations were performed on a well known pyroelectric material, LiTaO3, with various liquid substrates.

About this research paper

What this paper is about

The photopyroelectric calorimetry, in the standard (back) configuration, is applied in order to measure the thermal parameters of some pyroelectric materials. It is demonstrated that the method is able to simultaneously measure the thermal diffusivity and effusivity of a pyroelectric material. The information is obtained via a frequency scan of the amplitude or the phase of the pyroelectric signal; the measurements need no calibration. A combined amplitude-phase procedure, at a single frequency, leads to the same results. In the mean time, if the thermal parameters of the pyroelectric sensor are known, one can get the thermal effusivity of a sample acting in the experimental cell as a substrate. Investigations and theoretical simulations were performed on a well known pyroelectric material, LiTaO3, with various liquid substrates.

Why it matters

OpenAlex reports 32 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The photopyroelectric calorimetry, in the standard (back) configuration, is applied in order to measure the thermal parameters of some pyroelectric materials. It is demonstrated that the method is able to simultaneously measure the thermal diffusivity and effusivity of a pyroelectric material. The information is obtained via a frequency scan of the amplitude or the phase of the pyroelectric signal; the measurements need no calibration. A combined amplitude-phase procedure, at a single frequency, leads to the same results. In the mean time, if the thermal parameters of the pyroelectric sensor are known, one can get the thermal effusivity of a sample acting in the experimental cell as a substrate. Investigations and theoretical simulations were performed on a well known pyroelectric material, LiTaO3, with various liquid substrates.

Key concepts: Pyroelectricity, Thermal effusivity, Thermal diffusivity, Materials science, Thermal, Calibration, Amplitude, Thermal conductivity measurement

Related papers

Back to paper searchBrowse research topicsOriginal source
The application of the photopyroelectric method for measuring the thermal parameters of pyroelectric materials — Research Paper | ScholarLens