Comparison between fluctuating PEEP and conventional PEEP in dogs with lung injury induced by blood aspiration
Jiro Sato, Hideo Inaba, H Uchida, M. Sakurada, Tetsuro Ohwada, Tadanobu Mizuguchi
Abstract
Jiro Sato, Hideo Inaba, H Uchida, M. Sakurada, Tetsuro Ohwada, Tadanobu Mizuguchi
Abstract
It has been documented that in some patients with acute hypoxic respiratory failure the application of positive end-expiratory pressure (PEEP) may produce no improvement or even a deterioration of pulmonary oxygenation due to an increase in ventilation-perfusion mismatching. Fluctuating PEEP (F-PEEP) is a newly developed PEEP in which end-expiratory pressure (EEP) is periodically changed within a certain range. In a dog model with localized lung injury induced by the aspiration of non-heparinized blood (2 ml.kg body weight-1), F-PEEP in which the EEP was periodically changed from 0.5 to 1.5 kPa at frequencies of 10 min, and conventional PEEP with 3 different fixed EEPs, 0.5, 1.0 and 1.5 kPa (C-PEEP0.5, C-PEEP1.0 and C-PEEP1.5) were each applied for 60 min. F-PEEP produced a periodical change in PaO2 and hemodynamic variables including cardiac output, and in comparison with C-PEEP0.5, C-PEEP1.0 and C-PEEP1.5, a significantly greater improvement of A-aDO2 and dynamic compliance with relatively large cardiac output in the low EEP phase. These results suggest that F-PEEP is a useful mode of artificial ventilation for treating some kinds of acute hypoxic respiratory failure due to increased ventilation-perfusion mismatching.
OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
It has been documented that in some patients with acute hypoxic respiratory failure the application of positive end-expiratory pressure (PEEP) may produce no improvement or even a deterioration of pulmonary oxygenation due to an increase in ventilation-perfusion mismatching. Fluctuating PEEP (F-PEEP) is a newly developed PEEP in which end-expiratory pressure (EEP) is periodically changed within a certain range. In a dog model with localized lung injury induced by the aspiration of non-heparinized blood (2 ml.kg body weight-1), F-PEEP in which the EEP was periodically changed from 0.5 to 1.5 kPa at frequencies of 10 min, and conventional PEEP with 3 different fixed EEPs, 0.5, 1.0 and 1.5 kPa (C-PEEP0.5, C-PEEP1.0 and C-PEEP1.5) were each applied for 60 min. F-PEEP produced a periodical change in PaO2 and hemodynamic variables including cardiac output, and in comparison with C-PEEP0.5, C-PEEP1.0 and C-PEEP1.5, a significantly greater improvement of A-aDO2 and dynamic compliance with relatively large cardiac output in the low EEP phase. These results suggest that F-PEEP is a useful mode of artificial ventilation for treating some kinds of acute hypoxic respiratory failure due to increased ventilation-perfusion mismatching.
Key concepts: Medicine, Lung, Anesthesia, Positive end-expiratory pressure, Internal medicine