2009Biology of the NeonateRequires access

Use of Dual-Energy X-Ray Absorptiometry for the Measurements of Small Quantities of Mineral

Alexandre Lapillonne, P Braillon, Olivier Claris, Pui S. Ho, Pierre D. Delmas, Bernard L. Salle

Open publisher page 5 citations

Abstract

The aim of the study was to assess the precision and the accuracy of whole-body dual-energy X-ray absorptiometry (DXA) measurements of low quantities of mineral. Six stillborn infants were measured three times in order to assess the precision in vivo. Powdered bone tablets were also measured three times separately or in compact groups (0.32-41.7 g of hydroxyapatite) by whole-body DXA. Mean correlation coefficients were 6.85 +/- 5.99 and 6.74 +/- 6.58% in vivo and in vitro, respectively. DXA-based estimates of the tablets were highly correlated with the actual bone mineral content (BMC; r = 0.99, p = 0.0001). The mean difference between DXA values and the reference values was 2.55 +/- 10.93%, but the agreement between DXA results and reference values rose to 3.99 +/- 3.49% for BMC above 10 g. Very small amounts of mineral can be measured by whole-body DXA, but assessment of an infant with a BMC less than 10 g should be made with care.

About this research paper

What this paper is about

The aim of the study was to assess the precision and the accuracy of whole-body dual-energy X-ray absorptiometry (DXA) measurements of low quantities of mineral. Six stillborn infants were measured three times in order to assess the precision in vivo. Powdered bone tablets were also measured three times separately or in compact groups (0.32-41.7 g of hydroxyapatite) by whole-body DXA. Mean correlation coefficients were 6.85 +/- 5.99 and 6.74 +/- 6.58% in vivo and in vitro, respectively. DXA-based estimates of the tablets were highly correlated with the actual bone mineral content (BMC; r = 0.99, p = 0.0001). The mean difference between DXA values and the reference values was 2.55 +/- 10.93%, but the agreement between DXA results and reference values rose to 3.99 +/- 3.49% for BMC above 10 g. Very small amounts of mineral can be measured by whole-body DXA, but assessment of an infant with a BMC less than 10 g should be made with care.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The aim of the study was to assess the precision and the accuracy of whole-body dual-energy X-ray absorptiometry (DXA) measurements of low quantities of mineral. Six stillborn infants were measured three times in order to assess the precision in vivo. Powdered bone tablets were also measured three times separately or in compact groups (0.32-41.7 g of hydroxyapatite) by whole-body DXA. Mean correlation coefficients were 6.85 +/- 5.99 and 6.74 +/- 6.58% in vivo and in vitro, respectively. DXA-based estimates of the tablets were highly correlated with the actual bone mineral content (BMC; r = 0.99, p = 0.0001). The mean difference between DXA values and the reference values was 2.55 +/- 10.93%, but the agreement between DXA results and reference values rose to 3.99 +/- 3.49% for BMC above 10 g. Very small amounts of mineral can be measured by whole-body DXA, but assessment of an infant with a BMC less than 10 g should be made with care.

Key concepts: Dual-energy X-ray absorptiometry, Bone mineral, Mineral, Dual energy, Medicine, Mineralogy, Nuclear medicine, Chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Use of Dual-Energy X-Ray Absorptiometry for the Measurements of Small Quantities of Mineral — Research Paper | ScholarLens