The influence of GoldbonderTM and pre‐heat treatment on the adhesion of titanium alloy and porcelain
Kenji Yamada, Toshihiro Onizuka, Kazuhiko Endo, Hajime Ohno, Michael Vincent Swain
Abstract
Kenji Yamada, Toshihiro Onizuka, Kazuhiko Endo, Hajime Ohno, Michael Vincent Swain
Abstract
The present study examines the influence of a goldbonder and pre-heat treatment of the titanium on the adhesion of porcelain. Three groups of titanium substrates were given various heat treatments, namely; none, 200 degrees and 600 degrees C, respectively before applying goldbonder. The surfaces of the titanium specimens following heat treatment were examined with an electron spectroscopy for chemical analysis (ESCA). The adhesion strength was measured by the strain energy release rate (G), which was proposed by Suansuwan N and Swain MV (Int J Prosthodont. 1999;12:547). After bonding porcelain onto titanium substrates with the aid of the goldbonder, the porcelain side of specimens was notched to the interface with a thin diamond saw. Then the samples were subject to a four-point bending test. Following fracture testing, specimens were examined with a scanning electron microscope (SEM) and SEM with energy-dispersive spectroscopic analysis (EDS). The mean G-values were 38.87, 28.64 and 16.33 J m(-2), respectively. ESCA analysis showed the composition of aluminium of the surface of 600 degrees C pre-heat treatment became richer than that of the others. SEM images of the fracture surfaces showed that for the 600 degrees C pre-heat treatment fracture occurred within the oxidation layer on the titanium. High temperature pre-heat treatment prior to bonding significantly reduces porcelain bonded to titanium with the goldbonder. The Influence of Goldbonder and Pre-heat Treatment on the Adhesion of Titanium Alloy and Porcelain.
OpenAlex reports 17 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The present study examines the influence of a goldbonder and pre-heat treatment of the titanium on the adhesion of porcelain. Three groups of titanium substrates were given various heat treatments, namely; none, 200 degrees and 600 degrees C, respectively before applying goldbonder. The surfaces of the titanium specimens following heat treatment were examined with an electron spectroscopy for chemical analysis (ESCA). The adhesion strength was measured by the strain energy release rate (G), which was proposed by Suansuwan N and Swain MV (Int J Prosthodont. 1999;12:547). After bonding porcelain onto titanium substrates with the aid of the goldbonder, the porcelain side of specimens was notched to the interface with a thin diamond saw. Then the samples were subject to a four-point bending test. Following fracture testing, specimens were examined with a scanning electron microscope (SEM) and SEM with energy-dispersive spectroscopic analysis (EDS). The mean G-values were 38.87, 28.64 and 16.33 J m(-2), respectively. ESCA analysis showed the composition of aluminium of the surface of 600 degrees C pre-heat treatment became richer than that of the others. SEM images of the fracture surfaces showed that for the 600 degrees C pre-heat treatment fracture occurred within the oxidation layer on the titanium. High temperature pre-heat treatment prior to bonding significantly reduces porcelain bonded to titanium with the goldbonder. The Influence of Goldbonder and Pre-heat Treatment on the Adhesion of Titanium Alloy and Porcelain.
Key concepts: Titanium, Materials science, Scanning electron microscope, Composite material, Adhesion, Aluminium, Energy-dispersive X-ray spectroscopy, Titanium alloy