2013•Journal of Pharmaceutical AnalysisOpen access

Simultaneous determination of ezetimibe and simvastatin in rat plasma by stable-isotope dilution LC-ESI–MS/MS and its application to a pharmacokinetic study

Sireesha R. Karanam, Prakash Katakam, Babu Rao Chandu, Nagiat T. Hwisa, Shanta Kumari Adiki

Open full text 19 citations

Abstract

A simple, sensitive and specific liquid chromatography–tandem mass spectrometry method was developed for simultaneous quantification of ezetimibe and simvastatin in rat plasma. The deuterium isotopes: ezetimibe d4 and simvastatin d6 were used as internal standards for ezetimibe and simvastatin, respectively. MS/MS detection involved a switch of electron spray ionization mode from negative to positive at retention time 3.01 min. Samples were extracted from plasma by liquid–liquid extraction using tertiary butyl methyl ether. Chromatographic separation was achieved with Agilent Eclipse XBD-C18 column using mobile phase that consisted of a mixture of ammonium acetate (pH4.5; 10 mM)–acetonitrile (25:75 v/v). The method was linear and validated over the concentration range of 0.2–40.0 ng/mL for simvastatin and 0.05–15.0 ng/mL for ezetimibe. The transitions selected were m/z 408.3→271.1 and m/z 412.0→275.10 for ezetimibe and ezetimibe d4, and m/z 419.30→285.20 and m/z 425.40→199.20 for simvastatin and simvastatin d6. Intra- and inter-batch precisions for ezetimibe were 1.6–14.8% and 2.1–13.4%; and for simvastatin 0.94–9.56% and 0.79–12%, respectively. The proposed method was sensitive, selective, precise and accurate for the quantification of ezetimibe and simvastatin simultaneously in rat plasma. The method was successfully applied to a pharmacokinetic study by oral co-administration of ezetimibe and simvastatin in SD rats.

Open-access reader

About this research paper

What this paper is about

A simple, sensitive and specific liquid chromatography–tandem mass spectrometry method was developed for simultaneous quantification of ezetimibe and simvastatin in rat plasma. The deuterium isotopes: ezetimibe d4 and simvastatin d6 were used as internal standards for ezetimibe and simvastatin, respectively. MS/MS detection involved a switch of electron spray ionization mode from negative to positive at retention time 3.01 min. Samples were extracted from plasma by liquid–liquid extraction using tertiary butyl methyl ether. Chromatographic separation was achieved with Agilent Eclipse XBD-C18 column using mobile phase that consisted of a mixture of ammonium acetate (pH4.5; 10 mM)–acetonitrile (25:75 v/v). The method was linear and validated over the concentration range of 0.2–40.0 ng/mL for simvastatin and 0.05–15.0 ng/mL for ezetimibe. The transitions selected were m/z 408.3→271.1 and m/z 412.0→275.10 for ezetimibe and ezetimibe d4, and m/z 419.30→285.20 and m/z 425.40→199.20 for simvastatin and simvastatin d6. Intra- and inter-batch precisions for ezetimibe were 1.6–14.8% and 2.1–13.4%; and for simvastatin 0.94–9.56% and 0.79–12%, respectively. The proposed method was sensitive, selective, precise and accurate for the quantification of ezetimibe and simvastatin simultaneously in rat plasma. The method was successfully applied to a pharmacokinetic study by oral co-administration of ezetimibe and simvastatin in SD rats.

Why it matters

OpenAlex reports 19 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A simple, sensitive and specific liquid chromatography–tandem mass spectrometry method was developed for simultaneous quantification of ezetimibe and simvastatin in rat plasma. The deuterium isotopes: ezetimibe d4 and simvastatin d6 were used as internal standards for ezetimibe and simvastatin, respectively. MS/MS detection involved a switch of electron spray ionization mode from negative to positive at retention time 3.01 min. Samples were extracted from plasma by liquid–liquid extraction using tertiary butyl methyl ether. Chromatographic separation was achieved with Agilent Eclipse XBD-C18 column using mobile phase that consisted of a mixture of ammonium acetate (pH4.5; 10 mM)–acetonitrile (25:75 v/v). The method was linear and validated over the concentration range of 0.2–40.0 ng/mL for simvastatin and 0.05–15.0 ng/mL for ezetimibe. The transitions selected were m/z 408.3→271.1 and m/z 412.0→275.10 for ezetimibe and ezetimibe d4, and m/z 419.30→285.20 and m/z 425.40→199.20 for simvastatin and simvastatin d6. Intra- and inter-batch precisions for ezetimibe were 1.6–14.8% and 2.1–13.4%; and for simvastatin 0.94–9.56% and 0.79–12%, respectively. The proposed method was sensitive, selective, precise and accurate for the quantification of ezetimibe and simvastatin simultaneously in rat plasma. The method was successfully applied to a pharmacokinetic study by oral co-administration of ezetimibe and simvastatin in SD rats.

Key concepts: Chemistry, Simvastatin, Isotope dilution, Chromatography, Pharmacokinetics, Ezetimibe, Plasma, Dilution

Related papers

Back to paper searchBrowse research topicsOriginal source
Simultaneous determination of ezetimibe and simvastatin in rat plasma by stable-isotope dilution LC-ESI–MS/MS and its application to a pharmacokinetic study — Research Paper | ScholarLens