1991Ultrasound in Obstetrics and GynecologyOpen access

Ultrasound measurement of the fetal head: computer versus operator

Ivan E. Zador, Valiollah Salari, Lawrence Chik, Robert J. Sokol

Open full text 11 citations

Abstract

In obstetrical ultrasound practice, biparietal diameter, occipito-frontal diameter and head circumference are among the most commonly used fetal measurements. To minimize the limitations associated with manual measurement, we have undertaken an investigation with a focus on (1) the design of a personal computer-based system for automated measurements of biparietal diameter, occipito-frontal diameter and head circumference, and (2) integration of such a system (including measurements of abdomen and femur) into the routine obstetrical ultrasound examination. This report presents preliminary results of a comparison of computer-determined fetal head measurements with those obtained by an operator. Data were obtained from 75 consecutive singleton fetal ultrasound examinations free of any obvious structural anomalies. The computer obtained acceptable measurements of biparietal diameter, occipito-frontal diameter and head circumference from 74 images and failed on one image. There was a highly significant correlation between computer-determined measurements of biparietal diameter (r = 0.986), occipito-frontal diameter (r = 0.958) and head circumference (r = 0.972) and those obtained by the operators. The mean measurement difference (computer minus operator) was 1.87 +/- 1.94 mm for biparietal diameter, 2.82 +/- 4.13 mm for occipito-frontal diameter and -0.36 +/- 9.87 mm for head circumference. These differences were independent of the operator's identity, the instrument used and gestational age. The key finding of this study is that, with the use of inexpensive personal computer technology, it is possible to design and implement a system that can give fetal head measurements which correlate highly with manual determination by a skilled operator and which take a fraction of the time.

Open-access reader

About this research paper

What this paper is about

In obstetrical ultrasound practice, biparietal diameter, occipito-frontal diameter and head circumference are among the most commonly used fetal measurements. To minimize the limitations associated with manual measurement, we have undertaken an investigation with a focus on (1) the design of a personal computer-based system for automated measurements of biparietal diameter, occipito-frontal diameter and head circumference, and (2) integration of such a system (including measurements of abdomen and femur) into the routine obstetrical ultrasound examination. This report presents preliminary results of a comparison of computer-determined fetal head measurements with those obtained by an operator. Data were obtained from 75 consecutive singleton fetal ultrasound examinations free of any obvious structural anomalies. The computer obtained acceptable measurements of biparietal diameter, occipito-frontal diameter and head circumference from 74 images and failed on one image. There was a highly significant correlation between computer-determined measurements of biparietal diameter (r = 0.986), occipito-frontal diameter (r = 0.958) and head circumference (r = 0.972) and those obtained by the operators. The mean measurement difference (computer minus operator) was 1.87 +/- 1.94 mm for biparietal diameter, 2.82 +/- 4.13 mm for occipito-frontal diameter and -0.36 +/- 9.87 mm for head circumference. These differences were independent of the operator's identity, the instrument used and gestational age. The key finding of this study is that, with the use of inexpensive personal computer technology, it is possible to design and implement a system that can give fetal head measurements which correlate highly with manual determination by a skilled operator and which take a fraction of the time.

Why it matters

OpenAlex reports 11 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In obstetrical ultrasound practice, biparietal diameter, occipito-frontal diameter and head circumference are among the most commonly used fetal measurements. To minimize the limitations associated with manual measurement, we have undertaken an investigation with a focus on (1) the design of a personal computer-based system for automated measurements of biparietal diameter, occipito-frontal diameter and head circumference, and (2) integration of such a system (including measurements of abdomen and femur) into the routine obstetrical ultrasound examination. This report presents preliminary results of a comparison of computer-determined fetal head measurements with those obtained by an operator. Data were obtained from 75 consecutive singleton fetal ultrasound examinations free of any obvious structural anomalies. The computer obtained acceptable measurements of biparietal diameter, occipito-frontal diameter and head circumference from 74 images and failed on one image. There was a highly significant correlation between computer-determined measurements of biparietal diameter (r = 0.986), occipito-frontal diameter (r = 0.958) and head circumference (r = 0.972) and those obtained by the operators. The mean measurement difference (computer minus operator) was 1.87 +/- 1.94 mm for biparietal diameter, 2.82 +/- 4.13 mm for occipito-frontal diameter and -0.36 +/- 9.87 mm for head circumference. These differences were independent of the operator's identity, the instrument used and gestational age. The key finding of this study is that, with the use of inexpensive personal computer technology, it is possible to design and implement a system that can give fetal head measurements which correlate highly with manual determination by a skilled operator and which take a fraction of the time.

Key concepts: Biparietal diameter, Medicine, Fetal head, Ultrasound, Head circumference, Cephalometry, Nuclear medicine, Personal computer

Related papers

Back to paper searchBrowse research topicsOriginal source
Ultrasound measurement of the fetal head: computer versus operator — Research Paper | ScholarLens