1996ASAIO JournalRequires access

Clinical Heparin Coated Cardiopulmonary Bypass

Joseph S. Ladowski, M H Schatzilein, Alan C. Peterson, W. P. Deschner, Robert J. Matheis, M. Ellenwood, John R. Bach, Leni Moldovan, D. McKamey

Open publisher page 4 citations

Abstract

The authors compared blood loss, transfusion requirements, and heparin doses for reoperative cardiac surgery using either: a) a Duraflow (Baxter Corporation, Irvine, CA) heparin coated cardiopulmonary bypass (CPB) system or b) standard CPB. Twenty patients underwent redo cardiac surgery while supported with heparin coated CPB, and 17 patients underwent redo cardiac surgery with standard CPB. The following data are presented as mean +/- standard deviation. The heparin coated CPB circuit group received significantly less heparin than the standard CPB group (322 +/- 80 IU/kg versus 448 +/- 80 IU/kg, p < 0.01). There was no difference in blood loss in the first 24 postoperative hrs or mean transfusion requirements for the two groups. Despite the reduced dose of heparin, the mean activated clotting time in the heparin coated group was similar to the mean activated clotting time of the standard CPB group (577 +/- 98 sec versus 612 +/- 117 sec, p = ns). In conclusion, heparin coated CPB without reduced activated clotting time does not reduce transfusion requirements or blood loss in reoperative cardiac surgery. The heparin coated CPB system allows maintenance of the activated clotting time level despite reduced heparin doses.

About this research paper

What this paper is about

The authors compared blood loss, transfusion requirements, and heparin doses for reoperative cardiac surgery using either: a) a Duraflow (Baxter Corporation, Irvine, CA) heparin coated cardiopulmonary bypass (CPB) system or b) standard CPB. Twenty patients underwent redo cardiac surgery while supported with heparin coated CPB, and 17 patients underwent redo cardiac surgery with standard CPB. The following data are presented as mean +/- standard deviation. The heparin coated CPB circuit group received significantly less heparin than the standard CPB group (322 +/- 80 IU/kg versus 448 +/- 80 IU/kg, p < 0.01). There was no difference in blood loss in the first 24 postoperative hrs or mean transfusion requirements for the two groups. Despite the reduced dose of heparin, the mean activated clotting time in the heparin coated group was similar to the mean activated clotting time of the standard CPB group (577 +/- 98 sec versus 612 +/- 117 sec, p = ns). In conclusion, heparin coated CPB without reduced activated clotting time does not reduce transfusion requirements or blood loss in reoperative cardiac surgery. The heparin coated CPB system allows maintenance of the activated clotting time level despite reduced heparin doses.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The authors compared blood loss, transfusion requirements, and heparin doses for reoperative cardiac surgery using either: a) a Duraflow (Baxter Corporation, Irvine, CA) heparin coated cardiopulmonary bypass (CPB) system or b) standard CPB. Twenty patients underwent redo cardiac surgery while supported with heparin coated CPB, and 17 patients underwent redo cardiac surgery with standard CPB. The following data are presented as mean +/- standard deviation. The heparin coated CPB circuit group received significantly less heparin than the standard CPB group (322 +/- 80 IU/kg versus 448 +/- 80 IU/kg, p < 0.01). There was no difference in blood loss in the first 24 postoperative hrs or mean transfusion requirements for the two groups. Despite the reduced dose of heparin, the mean activated clotting time in the heparin coated group was similar to the mean activated clotting time of the standard CPB group (577 +/- 98 sec versus 612 +/- 117 sec, p = ns). In conclusion, heparin coated CPB without reduced activated clotting time does not reduce transfusion requirements or blood loss in reoperative cardiac surgery. The heparin coated CPB system allows maintenance of the activated clotting time level despite reduced heparin doses.

Key concepts: Activated clotting time, Cardiopulmonary bypass, Heparin, Medicine, Anesthesia, Cardiac surgery, Surgery