A Postprocessing Dual Energy Technique for Vertebral CT Densitometry

A. M. Laval-Jeantet, Christopher E. Cann, B Roger, P. Dallant

Open publisher page 62 citations

Abstract

The influence of the fat content in the cancellous bone on CT densitometry was measured on the excised vertebrae from 42 elderly human subjects. Using single energy CT, the decrease of the measured mineral content was 12% for a fat content of 10% by volume at a mean mineral content of 100-110 mg/cm3. Using a dual calibration at 85 and 130 kVp with reference to K2HPO4 for mineral and to alcohol for fat, our experiment showed that the mineral content of the vertebra can be measured with an accuracy of 6% referred to the ash-weight.

About this research paper

What this paper is about

The influence of the fat content in the cancellous bone on CT densitometry was measured on the excised vertebrae from 42 elderly human subjects. Using single energy CT, the decrease of the measured mineral content was 12% for a fat content of 10% by volume at a mean mineral content of 100-110 mg/cm3. Using a dual calibration at 85 and 130 kVp with reference to K2HPO4 for mineral and to alcohol for fat, our experiment showed that the mineral content of the vertebra can be measured with an accuracy of 6% referred to the ash-weight.

Why it matters

OpenAlex reports 62 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The influence of the fat content in the cancellous bone on CT densitometry was measured on the excised vertebrae from 42 elderly human subjects. Using single energy CT, the decrease of the measured mineral content was 12% for a fat content of 10% by volume at a mean mineral content of 100-110 mg/cm3. Using a dual calibration at 85 and 130 kVp with reference to K2HPO4 for mineral and to alcohol for fat, our experiment showed that the mineral content of the vertebra can be measured with an accuracy of 6% referred to the ash-weight.

Key concepts: Medicine, Densitometry, Bone mineral content, Dual energy, Nuclear medicine, Vertebra, Bone mineral, Cancellous bone