1990Medical PhysicsRequires access

Calculation of three‐dimensional photon primary absorbed dose using forward and backward spread dose‐distribution functions

Akira Iwasaki

Open publisher page 10 citations

Abstract

This paper describes a method of calculating three-dimensional (3-D) photon primary absorbed dose in a homogeneous or heterogeneous medium. The method is based on a technique of convolving a pair of forward and backward spread dose-distribution functions with the primary water collision kerma distribution. Both spread dose-distribution functions can be constructed by analyzing the zero-area tissue-maximum ratio, the primary absorbed dose near the beam exit surface, and the laterally spread dose distribution. Primary absorbed dose calculations are performed along the beam axis for 10-MV x rays. The characteristic patterns of primary dose in heterogeneous phantoms containing an aluminum or lunglike material slab can be obtained.

About this research paper

What this paper is about

This paper describes a method of calculating three-dimensional (3-D) photon primary absorbed dose in a homogeneous or heterogeneous medium. The method is based on a technique of convolving a pair of forward and backward spread dose-distribution functions with the primary water collision kerma distribution. Both spread dose-distribution functions can be constructed by analyzing the zero-area tissue-maximum ratio, the primary absorbed dose near the beam exit surface, and the laterally spread dose distribution. Primary absorbed dose calculations are performed along the beam axis for 10-MV x rays. The characteristic patterns of primary dose in heterogeneous phantoms containing an aluminum or lunglike material slab can be obtained.

Why it matters

OpenAlex reports 10 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This paper describes a method of calculating three-dimensional (3-D) photon primary absorbed dose in a homogeneous or heterogeneous medium. The method is based on a technique of convolving a pair of forward and backward spread dose-distribution functions with the primary water collision kerma distribution. Both spread dose-distribution functions can be constructed by analyzing the zero-area tissue-maximum ratio, the primary absorbed dose near the beam exit surface, and the laterally spread dose distribution. Primary absorbed dose calculations are performed along the beam axis for 10-MV x rays. The characteristic patterns of primary dose in heterogeneous phantoms containing an aluminum or lunglike material slab can be obtained.

Key concepts: Absorbed dose, Percentage depth dose curve, Kerma, Dosimetry, Photon, Beam (structure), Materials science, Distribution (mathematics)

Related papers

Back to paper searchBrowse research topicsOriginal source
Calculation of three‐dimensional photon primary absorbed dose using forward and backward spread dose‐distribution functions — Research Paper | ScholarLens