Simulation of current active power filter and its control methods
Xiaomeng Li, Wu Jian, Xu Dianguo
Abstract
Xiaomeng Li, Wu Jian, Xu Dianguo
Abstract
Active Power Filters is an effective means to cope with harmonic pollution in power network. This paper describes the basic operation principle and control methods of the current-source active power filter, and focusing on triangle modulation strategy of APF, detailed analysis of occurrence and distribution of the signals. When the APF load current detected includes capacitive load current, with the compensation coefficient change, the system has potential risk of resonance, affecting the stability and the harmonic compensation. Then, a control method in which both the supply current and load current are detected to control the output current of parallel active power filter is proposed. The control method makes the system work effectively when the capacitor current is included in the detected load current, and it can be easily implemented by the APF itself. The simulation results indicate that the active power filter's stability is high and its harmonics compensation performance is excellent. Finally, simulations results are presented to demonstrate the conclusions of the proposed control method.
OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Active Power Filters is an effective means to cope with harmonic pollution in power network. This paper describes the basic operation principle and control methods of the current-source active power filter, and focusing on triangle modulation strategy of APF, detailed analysis of occurrence and distribution of the signals. When the APF load current detected includes capacitive load current, with the compensation coefficient change, the system has potential risk of resonance, affecting the stability and the harmonic compensation. Then, a control method in which both the supply current and load current are detected to control the output current of parallel active power filter is proposed. The control method makes the system work effectively when the capacitor current is included in the detected load current, and it can be easily implemented by the APF itself. The simulation results indicate that the active power filter's stability is high and its harmonics compensation performance is excellent. Finally, simulations results are presented to demonstrate the conclusions of the proposed control method.
Key concepts: Active filter, Harmonics, Power factor, AC power, Control theory (sociology), Harmonic, Volt-ampere, Compensation (psychology)